Tastenkombination zum
Kalibrieren des Dolly
Press and hold the SPD-button, then switch the column on by pressing the ON/OFF button on
the HCU whilst holding the SPD button pressed.
Info:
In cable mode the column is switched on from the HCU.
As soon as the HCU LED is on the SPD-button can be released.
The
Display shows „CAL DOLLY“.
Press the CAL button (RMP) button to begin calibrating.
The column will automatically drive to its lowest position and then to the maximum height.
Upon reaching the maximum height press EXIT.
During calibration the column will drive slowly to the bottom position and then to the top
position and finally return to the starting position
and the display will show “PLEASE WAIT”.
When the display shows “DONE” press the EXIT button to leave the calibration mode.