Operating Instructions MSA 2 MULTI
Fusion process
9
2 Fusion
process
2.1 Switching
On
Before connecting the machine to the power source, please
read the chapter 6 ‘Technical characteristics‘ and check the
input voltage. If a generator is used, this has to be started
before connecting the electro-fusion unit and must supply a
constant output voltage! Any sudden changes could
compromise the correct welding result and/or damage the
control unit.
Connect the machine to the power mains or generator when the
generator is already started. At power on the display shows the
machine information: model, version and serial number.
2.2 Material
selection
The first step is the plastic material selection: the MSA 2 MULTI
can weld PE, PP-R, PP/PVDF or PB INSTAFLEX fittings. As the
fusion parameters change depending on the material, the user
has to set the proper one. This shall be done reading with the
scanner the desired barcode, out of the 4 shown below
This must be done, when the display is showing the “connect
fitting” window:
MSA 2 MULTI
V 2.01
S156A6308001