Operating Instructions MSA 2 MULTI
Introduction
7
1.2.6 Welding
Cable
The fusion cable shall be connected to the fitting pins. As
standard the terminals are supplied with straight female
connectors, Ø4mm.
1.3
Barcode Reader Scanner
The barcode scanner allows a quick reading of welding
parameters by reading the related barcode, pointing the barcode
(at a distance of 10-15 cm) and pressing its button.
The successful reading is confirmed by special acoustic tones
and a display change. In case of drawbacks, to check if the
barcode reader is damaged, you can try to read for test purpose
the code printed below, when the machine shows the barcode
symbol.
If this code is read successfully, the issue is not on the barcode
reader. After usage, remember to place the barcode scanner
into its protective case.
1.4
Extension Cables for Power Supply
To avoid excessive dissipation or brown out, on Extension
cables, use cables with section:
4mm² for cables
10m full-run;
6mm² for cables
30m full-run.