2.8 Fusion
process
2.8.1 Welding
phase
During the fusion process, the display shows the information
concerning the output voltage, the remaining fusion time and the
applied energy.
t = 0020s
Vo= 39.7V
E = 003.1kJ
N 150
The machine adjusts the fusion time according to the external
temperature and barcode information. Therefore the final fusion
time values might be slightly different from the nominal values,
captured from the barcode.
The fusion process can be stopped at any time by the operator
by pushing STOP/ESC (O). Then the fusion process
immediately stops and an error message occurs (see ‘Error
Messages’ chapter).
Stopping the on-going fusion process will result in a suspicious
welding: the responsability will be in charge of the operator.
When the fusion operation is going to finish, a repeated acoustic
signal alerts the user that the process is near to complete. As soon
as the fusion process is correctly concluded, the display shows
briefly the information concerning the real fusion time, the average
voltage and the total energy applied to the jointing. These data will
be part of the welding protocol stored into the internal memory.
t = 0040s
Vo= 39.6 V
E = 007.5kJ
N 150
PE
Summary of Contents for MSA 2 MULTI
Page 2: ......
Page 29: ...Operating Instructions MSA 2 MULTI Accident Prevention 27...
Page 30: ...Bedienungsanleitung GF Piping Systems MSA 2 MULTI Elektroschweissger t...
Page 32: ...Operating Instructions MSA 2 MULTI 30 8 6 Arbeitssicherheit 56 8 7 Entsorgung 56...
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......