Fusion process
Operating Instructions MSA 2 MULTI
14
In case of manual mode, the machine works in different ways,
depending on the material selection.
If the material selection is PE or PP-R, then time and voltage
values must be entered, pressing the START/OK ( I ) button to
go in “edit” mode and then using (
) and (
) to select the
required digits and (
) (
) to change field. Once the values are
entered, must be pushed START/OK ( I )
If the mode is PP, the manual mode is based on a list of
selectable items the user can see pressing the START button.
With (
) and (
) he can choose the fitting, confirming with the
START/OK button.
SeaDrainplus
d= 1. 5”
x4
12/06/12 15:50
If the mode is PB (INSTAFLEX), then the manual mode is also
based on a list of selectable items the user can see pressing the
START button. With (
) and (
) he can choose the fitting type,
confirming with the START/OK button.
INSTAFLEX
d125
12/06/12 15:50
As soon as the data are correctly read from the barcode or
selected manually, the machine confirms with a double acoustic
tone and show on the display a summary of the captured fusion
parameters: time, voltage and expected coil resistance.
t = 0040s
Vo= 39.5V
R = 07.45
12/06/12 15:50
25°C