258X Wiring
1.
Disconnect power on the 9900.
2.
Unplug the sensor connector from the S
3
L/Frequency input jack on the 9900 and connect the 0252 Tool in its place.
3.
Reconnect power to the 9900.
V+
DATA
GND
SHLD
USB
GND
Data
+5V out
Windows PC
White
Red
Disconnect power on the 9900 prior to proceeding.
If the 9900 is using the Direct Conductivity/Resistivity Module, the module will need to be removed from the 9900.
Refer to the Direct Conductivity/Resistivity Module Instruction Sheet for instructions.
4. After configuring the 9900, please disconnect the 0252 Tool and reconnect the Sensor.
2610 Wiring
9900 Wiring
Red
Black
White
USB
Windows PC
GND
Data
Shield
+
–
Power Supply
12 to 32 VDC
Brown, Blue, Green
No connection
CAUTION!
Do not connect power directly to
the 0252 Configuration Tool.
Improper power supply wiring
can cause damage to the 0252
hardware and computer.
Turn 24 VDC Power OFF when
wiring the magmeter.
IMPORTANT
The power supply connected
to the 258X must be rated for
12 to 24 VDC output at a
minimum of 10 watts for
correct operation.
IMPORTANT
The 258X must be set to S³L
mode before connecting to the
0252 Tool. Failure to set the
258X to S³L will prevent the
0252 application from
communicating with the 258X.
The Android or iOS app will be
required to set the 258X to
S³L mode.
3-2581
Black -
Red +
White
Red
Power cable
Output cable
Shield
Black
Brown
Shield
Blue used for
GF Config App password
reset only
S
3
L / Frequency
4 to 20 mA
(EMC enhancement)
24 VDC @ 1A min.
Power Supply
+
–
6
GF 0252 Configuration Tool
Summary of Contents for Signet 0252
Page 11: ...258X Operation 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 11 GF 0252 Configuration Tool...
Page 13: ...258X Calibration 6 7 8 9 10 11 13 GF 0252 Configuration Tool...
Page 19: ...2751 Calibration 5 6 7 8 9 10 11 12 19 GF 0252 Configuration Tool...
Page 20: ...2751 Calibration 13 14 15 16 17 20 GF 0252 Configuration Tool...
Page 22: ...9900 Operation 2 3 5a 5b General Software Operation pg 7 22 GF 0252 Configuration Tool...