The 0252 can serve as a field data logger to download data directly into a *.csv (Comma Separated Value) file.
NOTE:
The 0252 does NOT have internal memory to store data.
It must be connected to a computer to use the datalog function.
1.
Select the sensor type and click on
Read
.
2.
Click the
Monitor
tab to open the datalog setup window.
3.
Enter the Logging Interval. This value represents the time between log records.
The minimum interval is 1 second, and the maximum interval is 86400 seconds (24 hours).
Example: If the Log Interval is set to 60 seconds, the 0252 will record the temperature once every minute.
4. The 0252 saves data files in *.csv format. The maximum number of records allowed for this type of file is
65535 records.
If the logging interval is 60 seconds = 1092 hours of continuous recorded data.
5.
Click
Log
and enter the file name for the 0252 to store the recorded data and click Save.
6. Click
Log File
check box to enable logging. If you do not wish to save the data, skip to step 7.
7. Click
Graph
to start monitoring the sensor.