General Software Operation
Read
Loads the data from the connected device (sensor or transmitter) and updates the software’s display.
NOTE
: This will overwrite any changes made in the 0252 software since the last
Write
.
Write
Applies the data entered in the 0252 software to the connected device. Once you have entered the desired setting
changes in the software screens, press
Write
to load your new settings onto the connected device.
Save
Stores the entire 0252 settings configuration, as currently displayed in the application, to a specified location on your
computer. (You will be asked to select a file location and provide a file name)
Load
Opens a previously saved settings configuration file. See
Save
function above.
NOTE:
The file must be a 0252 settings configuration file.
The software will verify whether the user-selected file is the correct type.
Default
Resets all data on all application screens to a factory default condition. A confirmation dialog box will be presented with
a warning explaining all un-saved configuration information will be erased.
After resetting the software to a factory default condition, click
Write
to reset the connected device to a factory default
condition.
NOTE:
Performing the above reset to factory default condition will not change the input type on the
9900 Transmitter.
NOTE:
Certain sensors, 2250, 2450, and 258X will request sensor specific information for the default setting
such as range or size.
On all screens
Read, Write, Save, Load,
and
Default
buttons can be found in the lower right corner.
Sensor Operation
Application
settings:
2250
2350
2450
2750
2751
1
Engineering units
in., ft, cm, m
˚C or ˚F
psi, kpa, bar
pH or (ORP)
pH or (ORP)
Loop
Output settings:
2
4 mA
Set Point
Min
0
-10 ˚C (14 ˚F)
0
0 pH
(-1000 mV)
-1 pH
(-1999 mV)
Max
-XU:
276.8 in., 23.07 ft,
703.1 cm, 7.03 m
-XL:
1384.0 in, 115.33 ft,
3515.0 cm, 35.15 m
100 ˚C (212 ˚F)
psi: 10, 50, 250
kpa: (69, 344.7,
1723.7)
bar: (0.7, 3.5, 17.2)
14 pH
(2000 mV)
15 pH
(1999 mV)
3
20 mA
Set Point
Min
0
-10 ˚C (14 ˚F)
0
0 pH
(-1000 mV)
-1 pH
(-1999 mV)
Max
-XU:
276.8 in., 23.07 ft,
703.1 cm, 7.03 m
-XL:
1384.0 in, 115.33 ft,
3515.0 cm, 35.15 m
100 ˚C (212 ˚F)
psi: 10, 50, 250
kpa: (69, 344.7,
1723.7)
bar: (0.7, 3.5, 17.2)
14 pH
(2000 mV)
15 pH
(1999 mV)
Write
or
Save
settings:
4a
or
4b
Click “Write” to copy these settings to the product.
Click “Save” to save these settings to a local computer file for later use.
5
To use a saved file (from 4b):
1. Click “Load”
2. Navigate to the saved file
3. Select “Open”
4. Click “Write”
5. Click “Read” to confirm
7
GF 0252 Configuration Tool
Summary of Contents for Signet 0252
Page 11: ...258X Operation 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 11 GF 0252 Configuration Tool...
Page 13: ...258X Calibration 6 7 8 9 10 11 13 GF 0252 Configuration Tool...
Page 19: ...2751 Calibration 5 6 7 8 9 10 11 12 19 GF 0252 Configuration Tool...
Page 20: ...2751 Calibration 13 14 15 16 17 20 GF 0252 Configuration Tool...
Page 22: ...9900 Operation 2 3 5a 5b General Software Operation pg 7 22 GF 0252 Configuration Tool...