Powerturn
42
Settings
à
The illustrations for the EN class setting are only intended as a guide.
à
The closing torques to be observed at 0–4° door opening angle are listed in the table below.
à
Risk of faults on the drive. Do not exceed maximum closing torques.
DIN 18263-4
EN 4
EN 5
EN 6
EN 7
max. door width (mm) 1100
1250
1400
1600
0–4°
M
min.
[Nm] 26
37
54
87
Type of installation
Max. closing torque /
at 0–4° TÖW [Nm]
Setting the spring force
Transom installation hinge side rail
59 (70) *
EN4
EN5
EN6
Transom installation opposite hinge side rail
63 (65) *
EN4
EN5
EN6
Door installation hinge side rail
70 (78) *
EN4
EN5
EN6
Door installation opposite hinge side rail
59 (62) *
EN4
EN5
EN6
Door installation hinge side link arm
128 (128) *
EN6 EN7
Transom installation opposite hinge side
link arm
97 (123) *
EN6 EN7
*
Values in brackets at max. door opening angle 95°