Installation
7.2.2 Sensor cable guiding via door transmission cable in the case of transom installation
Preparing end cap
Cutting out a pocket (4) and drilling through the screw domes (5) is only necessary when a drip loop is used from
the sensor to the drive.
X
Remove the end caps from the packaging
and carefully detach the left-hand end
cap (2).
X
Dispose of the gate (3).
3
X
Cut the pocket (4) out of the end cap (2)
along the perforation.
X
Drill blind holes with a drilling diameter
of 2.5 mm on the screw domes (5).
2
4
5
X
Insert corrugated tube (8) into the wall
bracket (6).
X
Use the two enclosed screws (7) to install
the wall bracket (6) on the end cap (2).
2
6
7
8
X
Place the sensor cable in the corrugated
tube (8).
X
Connect sensor cable in accordance with
the installation instructions for the sen-
sor (9).
9