Preparing installation
6.2.5 Door installation, hinge side, with link arm
Hole pattern DIN left and DIN right reversed.
Fastening DIN left
Fastening DIN right
3
3
1
Dimensional reference centre of hinge
2
Directional arrow for precise positioning of the mounting plate
3
Hinge size 220 mm
Fasteners
Steel/ aluminium doors
Timber doors
Drive fastening
8 countersunk screws M6 × 25 and riveting nut M6
8 wood screws Ø6 × 50
Fastening of link arm
2 cylinder head screws M6 × 20 and riveting nut M6
2 wood screws Ø5 × 50
Fastening of connecting bracket 2 cylinder head screws M6 × 12 and riveting nut M6
2 wood screws Ø6 × 30
Space requirement and fastening of link arm
720
220
100
30
AV
X
1
X
2
0
16
72
30
46
102
50
66
122
AV Spindle extension
X
2
50
X
1
= 16 +
AV
30
42
7*
10
10
22
50
50
50
5
4
5
4
Base - Upper edge of door
5
Space requirement for sensors
*
important functional dimension