Faults and troubleshooting
Gewiss
Code
Error description
Solution
Position
Error 6
Error in the control of the socket-
outlet locking motor (it does not
shift from OPEN to CLOSED)
Manually check the mobility
of the pin by moving the red
lever on the back of the type 2
socket-outlet locking motor.
Error 7
Error in the control of the socket-
outlet locking motor (it does not
shift from CLOSED to OPEN)
Manually check the mobility
of the pin by moving the red
lever on the back of the type 2
socket-outlet locking motor.
Error 8
The energy meters are no longer
communicating with the elec-
tronic card
Check the connection of the
Modbus line.
Check the power supply to the
energy meters.
Check the energy meters are
working properly.
Check the correct numbering of
the component on the Modbus
line.