5.3 Restoring to Factory Default Settings
To restore the factory default settings, you can use the camera’s Web interface or operate
directly on the camera.
5.3.1 Using the Web Interface
For GV-Hybrid LPR Camera 20R / 10R / GV-IP LPR Camera 5R / GV-LPC1100, follow the
steps below to restore the factory default settings through the camera’s Web interface.
1. In the left menu of the
Web interface, Click
Tools
.
2. In
System Settings
field, click the
Load Default
button to restore the factory default
settings.
5.3.2 Directly on the Camera
For GV-IP LPR Camera 5R and GV-LPC1100, you can alternatively press the default button
inside the camera.
1. Keep the power and network cables connected to the camera.
2. Loosen the camera’s cover and remove the Silica Gel Bag.
3. Press and hold the default button for 8 seconds.
Figure 5-7
4. Release the default button. When the process of loading default settings is completed, the
camera reboots automatically.
5. Insert a new Silica Gel Bag and fasten the camera’s cover immediately.
102