LRV: Lower range value (0% point - 4 mA)
URV: Upper range value (100% point - 20 mA)
Note) If the set value of the LRV is outside the
range, an error also occurs (Setting ERROR) in
the URV setting, and vice versa.
The maximum setting range is ± 9999.
The URV may exceed the upper limit depending
on the change of the Unit. If that happens change
WKH859¿UVW
:KHQSUHVVLQJ&+1*!XQGHUGLVSOD\
c
, display
changes to the LRV and URV selection screen.
3UHVV/59!IRUSUHVHQWLQJWKHGLVSOD\IRUVHWWLQJ
the zero point range (display
e
).
3UHVV859!IRUSUHVHQWLQJWKHGLVSOD\IRUVHWWLQJ
the span range (display
f
).
8QGHUGLVSOD\V
f
or
f
, input zero point or span
YDOXHV3UHVV(17!DIWHUVHWWLQJ/59RU859
1RWHZKHQSUHVVLQJ±!XQGHUGLVSOD\
e
or
f
, negative value is available
.
Note : if the set value of the LRV is outside
the range, an error ("setting error") also occurs
in the URV setting, and vice versa.
The maximum setting range is ±99999.
The URV may exceed the upper limit depending
on the change of the UNIT.
,IWKDWKDSSHQVFKDQJHWKH859¿UVW
0HQX5DQJH/LPLW
Indicates the maximum measuring range of this
transmitter.
$IWHUVHWWLQJHQJLQHHULQJXQLWSUHVV,1&!NH\
to display RANGE LIMIT.
%\SUHVVLQJWKH,1&!NH\5$1*(VHWWLQJLPDJH
is displayed
.
INC
INC
INC
CL
CHNG
LRV
CL
URV
CL
ENT
CL
ENT
6-3: RANGE
WRITE
6-1: RANGE
CHANGE
LRV
XXX
.
X
kPa
< LRV > < URV > < CL >
URV
XXX
.
X
kPa
LRV
XXX
.
X
kPa
< LRV > < URV > < CL >
URV
XXX
.
X
kPa
LRV
XXX
.
X
kPa
< LRV > < URV > < CL >
URV
XXX
.
X
kPa
LRV
XXX
.
X
kPa
URV
XXX
.
X
kPa
LRV
XXX
.
X
kPa
URV
XXX
.
X
kPa
2
6-2: RANGE
CHANGE
3
6-2: RANGE
CHANGE
4
CHNG OK? < ENT/CL >
6-2: RANGE
CHANGE
5
6
1
6: RANGE
LRV
XXX
.
X
kPa
< INC > < CHANGE >
5: RANGE
LIMIT
XXX
kPa
< INC >
URV
XXX
.
X
kPa
Menu 4 : UNIT
To menu 7 : DAMPING
Output (mA)
URV
Maximum measuring range
Input
Normal
action
Reverse
action
4
LRV LRV
URV
20
Selectable setting range
The setting range of the transmitter is independent of the setting range of the indicator.
After changing the range in this menu, it is necessary to change the range in the LCD
indicator (menu G).
Using an analog indicator and the transmitter range is changed, replacement of the analog
indicator is required.
Important