100 fu-processx-en
www.georgin.com
Instruction manual - ProcessX
Seal tape
Bolt
Measurement
chamber cover
Gasket
Seal diaphragm
,QFDVHRIOHYHOWUDQVPLWWHU).(
To avoid any damage of the measuring cell, do not exceed the test pressure of
different cells (please refer to the technical data sheets of the concern transmitter)
Caution
!
Remember !
(6) After assembly, carry out a pressure test. Apply a pressure equal to 150% of the maximum
ZRUNLQJSUHVVXUHWRERWKÀDQJHVLGHKLJKSUHVV3DQGORZSUHVVXUH/PHD
-
surement chamber of the transmitter simultaneously during 15 minutes, and make sure
there is no leakage.
(1) Remove four hexagon socket head bolts with a torque wrench, etc..
(2) The process covers, the O-ring and the bolts and nuts can now be removed
(3) After disassembly, replace the faulty part with a new one.
(4) Before reassembly, clean carefully the O-ring face of casing cover with the soft cloth im-
mersed in water, alcohol, Freon TF or similar.
(5) Reassemble the detecting unit by reversing the disassembling procedure. The torque of
the bols of the process covers are indicated in the following table.
%ROWVL]H
%ROWPDWHULDO
7LJKWHQLQJWRUTXH
0D[LPXPZRUNLQJSUHVVXUH
0
&U0RVWHHO
1P
8SWRUDWHGÀDQJHSUHVVXUH
0
66
1P
8SWRUDWHGÀDQJHSUHVVXUH
0
66
1P
8SWRUDWHGÀDQJHSUHVVXUH