![Georges Renault CVIS II Operator'S Manual Download Page 60](http://html1.mh-extra.com/html/georges-renault/cvis-ii/cvis-ii_operators-manual_2215373060.webp)
6159932410-02
English
60 / 76
PRINTING FORMATS FOR RESULTS
5 - PC5-B FORMAT
xx
torque rate (ASCII notation)
e.g.:0.900 Nm/°
30 30 39 30 30
xx
xx
xx
xx
FF
end of frame character
Report per spindle: torque, angle,
torque rate:
F0
start of frame character
01
xx
report (in hexadecimal notation):
02
xx
00
03
TT torque report
xx
AA angle report
in binary notation
04
TR torque rate report
xx
where TR, AA or TT =01 if low report
05
11 if accept report
xx
10 if high report
06
00
on servodrive fault
xx
spindle belonging to reject group
07
cycle start drop
xx
cycle not completed for spindle
08
transducer fault
e.g.:if accept report for all the spindles
F0 01 3F 02 3F 03 3F 04 3F 05 3F 06 3F 07 3F 08 3F
Available parameters programmed for 1 spindle (x times the number of spindles):
01
spindle number in BCD
xx
minimum torque in 1/10th of Nm (ASCII notation)
e.g.: 90.0 Nm
30 30 39 30 30
xx
xx
xx
xx