PRINTING FORMATS FOR RESULTS
3 - PC4 FORMAT
Title
Names of the columns of the lines of results (depending on the language) and measuring unit on a 2nd line:
Result
In "Print at end of cycle" mode, the reading number is replaced by blanks.
If one of the values is missing in the unit (eg: torque rate), it is replaced by blanks.
Example of result: <CR>1223 02 03 00 18/04/03 09:03:45 0030.2 0120.5 0.5680 B <LF>
Report code
: The codes emitted on letters are used for digital report outputs or printouts. All these codes correspond to specific
displays. The table below shows the corresponding codes displayed. On the contrary, if some messages on the screen do not
correspond to a letter, it means that they are not emitted.
Rdg N°
Sp
Cy
Ph
Date
Time
Torque
Angle
Torque
rate
Stanby
characters
CR
Nm
dg
Nm/dg
xxxx
xx
xx
xx
xx/xx/xx
xx:xx:xx
xxxxxx
xxxxxx
xxxxxx
xxxxxx
xxx
1
char.
<CR>
4
Reading number
1
“ “
2
Spindle number
1
“ “
2
Cycle number
1
“ “
2
Phase number (= 2 blanks if cycle result)
1
“ “
8
Date in DD/MM/YY format
1
“ “
8
Time in hh:mm:ss format
2
“ “
6
Torque
2
“ “
6
Angle
2
“ “
6
Torque rate
2
“ “
6
Stanby characters
2
“ “
3
Report code in 3 letters
1
<LF>
Summary of Contents for CVIS II
Page 8: ...6159932410 02 English 8 76 SAFETY INSTRUCTIONS...
Page 12: ...6159932410 02 English 12 76 DESCRIPTION AND OPERATION...
Page 18: ...6159932410 02 English 18 76 INITIAL START UP...
Page 28: ...6159932410 02 English 28 76 RESULTS...
Page 48: ...6159932410 02 English 48 76 CONNECTIONS AND INSTALLATION...
Page 66: ...6159932410 02 English 66 76 CYCLE FLOWCHART AND TIMING CHART...