6159932410-02
English
23 / 76
PROGRAMMING
The tightening results of the Run Down speed phase are not saved.
3.4 - Final speed phase
Timeout
0 - 99 s. Phase running time.
Stop time
0.01 - 20 s.
The other instructions depend on the tightening strategy (see table below).
Torque
0 to max. value of the spindle.
Angle threshold
0 to max. value of the spindle.
Angle
0 - 9999.5°.
Other
press
W
to display the "Motor settings and other parameters" menu.
Optional: current monitoring.
The minimum and maximum electric current values are programmed experimentally: the max. current value must be read during
the test cycle, then the cycle must be run at least 3 times to define the electric current values to be programmed.
3.5 - Action on NOK phase
When a report is rejected (max. torque or angle reached, etc.), it is possible to apply a specific corrective action to the cycle, either
by stopping the cycle or by programming a corrective phase.
Examples: untighten the screw or the 2 screws, restart tightening, etc.
End
end of cycle.
Rrv+end
run end of cycle.
Jump
jump to phase "x".
Rrv+jump
Run r jump to phase "x".
Jump OK
jump to phase "x", if preceding phase has an accept report
Rrv+jump OK
run r jump to phase "x", if preceding phase has an accept report.
Run reverse time
0 - 99 s.
Thread type
right/left.
Rotational speed
0 - 100 % (0% to secure the motor in position). Up to 130% in some cases for the run down speed.
3.6 - Run reverse phase
Timeout
0 - 99 s. Phase running time.
Int. time
0.01 - 20 s.
Tightening
strategies
Instructions
Tor
que
Torque
+ angl
e
Angl
e +
to
rqu
e
Min, max torque
Target torque
Safety torque
Angle threshold
Min, max angle
Target angle
Safety angle
Summary of Contents for CVIS II
Page 8: ...6159932410 02 English 8 76 SAFETY INSTRUCTIONS...
Page 12: ...6159932410 02 English 12 76 DESCRIPTION AND OPERATION...
Page 18: ...6159932410 02 English 18 76 INITIAL START UP...
Page 28: ...6159932410 02 English 28 76 RESULTS...
Page 48: ...6159932410 02 English 48 76 CONNECTIONS AND INSTALLATION...
Page 66: ...6159932410 02 English 66 76 CYCLE FLOWCHART AND TIMING CHART...