6159932410-02
English
40 / 76
MAINTENANCE
The tool does not run in run
reverse mode.
The Tightening/Untightening
reversing gearbox is faulty.
The run reverse speed is set to 0.
30 In the "Tests, Inputs/outputs" menu, check the
switching of bit 7 when the reversing gearbox is
activated.
Check the "Spindle validation on run reverse"
parameter.
Test commutation between pins 2 and 5 of the
tool connector.
Check the value of the run reverse speed in the
"Parameters/Station" menu. If the reversing gear-
box is running correctly, the tool LEDs should
blink.
The motor stops suddenly; per-
forming another action on the
trigger starts the tool again.
The serial link between the tool
and the controller is disrupted.
This could be due to faulty shiel-
ding.
31 Check the value of the noise shown on the "tor-
que versus time" curve saved in the controller
memory.
Change the cables.
The tool does not run in tighte-
ning mode, but runs in run
reverse mode.
Loss of controller memory.
32 Check the presence of tightening cycles.
Check that the selected cycle is programmed cor-
rectly.
Transducer fault.
33 Refer to No. 18 and 22.
The Tightening/Untightening
reversing gearbox is stuck in run
reverse mode.
34 Refer to No. 30.
Symptoms
Possible causes
No
.
Check
Summary of Contents for CVIS II
Page 8: ...6159932410 02 English 8 76 SAFETY INSTRUCTIONS...
Page 12: ...6159932410 02 English 12 76 DESCRIPTION AND OPERATION...
Page 18: ...6159932410 02 English 18 76 INITIAL START UP...
Page 28: ...6159932410 02 English 28 76 RESULTS...
Page 48: ...6159932410 02 English 48 76 CONNECTIONS AND INSTALLATION...
Page 66: ...6159932410 02 English 66 76 CYCLE FLOWCHART AND TIMING CHART...