18
ENGLISH
(1)
If maintained, it prolongs the pause until disabled by the command (timer function)
(2)
If remaining pause time is shorter than 5 sec., when safety devices are released, it closes after 5 sec.
NB.:
Effects on other active pulse inputs in brackets.
CLOSED
OPEN
AT CLOSING
No effect
(OPEN-A/B disabled)
Opens the leaf or leaves
LOCKED
AT OPENING
No effect
LOGIC "B"
GATE STATUS
OPEN-A
No effect
(OPEN-A disabled)
No effect (OPEN-B disabled)
W.L.
lighted
flashing
lighted
lighted
No effect
(OPEN-A disabled)
OP/CLOS. SAFETY
DEVICE
CLOSING SAFETY DEVICES
OPENING SAFETY DEVICES
STOP
OPEN-B
Stops operation
(OPEN-A/B disabled)
No effect
OFF
Opens the leaf or leaves
No effect
Reverses at opening
No effect
No effect
(OPEN-A disabled)
No effect
(OPEN-B disabled)
No effect
(OPEN-A/B disabled)
Table 3/e
Closes the leaves or leaf
No effect
No effect
Closes the leaves or leaf
Stops operation
No effect
(OPEN-B disabled)
No effect
(OPEN-A disabled)
No effect
PULSES
No effect
(OPEN-B disabled)
Stops operation (OPEN-B disabled)
Stops operation
(OPEN-A/B disabled)
No effect
(OPEN-B disabled)
No effect
(OPEN-A disabled)
No effect
(OPEN-A disabled)
CLOSED
OPEN
AT CLOSING
AT OPENING
LOGIC "C"
GATE STATUS
OPEN-A
W.L.
lighted
flashing
lighted
OP/CLOS. SAFETY
DEVICE
CLOSING SAFETY DEVICES
OPENING SAFETY DEVICES
STOP
OPEN-B
Stops operation
(OPEN-A/B disabled)
No effect
OFF
Opens the leaf or leaves
No effect
Stops operation
No effect
Stops operation (OPEN-A disabled)
No effect
(OPEN-B disabled)
Closes the leaves or leaf
Stops operation
Stops operation
No effect
(OPEN-A disabled)
No effect
COMMANDS ALWAYS
PRESSED
No effect
(OPEN-B disabled)
No effect
(OPEN-B disabled)
No effect
(OPEN-A disabled)
No effect
(OPEN-A disabled)
No effect
(OPEN-A disabled)
No effect
(OPEN-B disabled)
Stops operation
(OPEN-A/B disabled)
Stops operation (OPEN-B disabled)
Table 3/f
PULSES