2 Locate the directional valve inside of the non-
steer axle and inspect the linkage for the
following:
· Lock nut is tight against yoke
· Yoke clevis pins are installed
· Cotter pins are installed through clevis pins
· Linkage is properly attached to
directional valve
a
directional valve
b
clevis pin with cotter pin (hidden)
c
yoke
d
lock nut
B-15
Test the Platform Self-leveling
Automatic platform self-leveling throughout
the full cycle of boom raising and lowering is
essential for safe machine operation. The
platform is maintained at level by the platform
leveling slave cylinder which operates in a closed
loop hydraulic circuit with the master cylinder
located at the base of the boom.
A platform self-leveling failure creates an unsafe
working condition for platform and
ground personnel.
1 Start the engine from the ground controls and
lower the boom into the stowed position.
2 Hold the function enable toggle switch to either
side and adjust the platform to a level position
using the platform level toggle switch.
3 Raise and lower the primary boom through
a full cycle.
Result: The platform should remain level at
all times to within ±5 degrees.
a
b
c
d
Summary of Contents for Z-45 XC
Page 1: ...First Edition Second Printing Part No 52709 Service Manual From Serial number 9998 to 21179...
Page 201: ......
Page 209: ......
Page 217: ......
Page 225: ......
Page 233: ......
Page 241: ......
Page 249: ......
Page 257: ......
Page 265: ......
Page 273: ......
Page 283: ......
Page 293: ......
Page 303: ......
Page 311: ......
Page 321: ......
Page 331: ......
Page 346: ...2WD Hydraulic Schematic First Edition Second Printing Section 6 Schematics...
Page 348: ...4WD Hydraulic Schematic First Edition Second Printing Section 6 Schematics...