Part No. 52709
Genie Z-45/25 & Genie Z-45/25J
4 - 9
First Edition • Second Printing
Section 4 • Scheduled Maintenance Procedures
TABLE
A
PROCEDURES
Deutz and Perkins Models:
· Fuel tank, shutoff valve, hoses and fittings,
fuel pump, fuel filter, fuel injection pumps and
fuel injectors.
Explosion and fire hazard. If a fuel
leak is discovered, keep any
additional personnel from entering
the area and do not operate the
machine. Repair the leak
immediately.
A-7
Check the Hydraulic Oil Level
Maintaining the hydraulic oil at the proper level is
essential to machine operation. Improper hydraulic
oil levels can damage hydraulic components. Daily
checks allow the inspector to identify changes in oil
level that might indicate the presence of hydraulic
system problems.
1 Be sure that the boom is in the stowed position,
then visually inspect the sight gauge located on
the side of the hydraulic oil tank.
Result: The hydraulic oil level should be within
the top 2 inches (5 cm) of the sight gauge.
2 Add oil as needed.
Hydraulic oil specifications
Hydraulic oil type
Dexron equivalent
Tank capacity
24 gallons
90.8 liters
Hydraulic system
(including tank)
30 gallons
113.6 liters
Summary of Contents for Z-45 XC
Page 1: ...First Edition Second Printing Part No 52709 Service Manual From Serial number 9998 to 21179...
Page 201: ......
Page 209: ......
Page 217: ......
Page 225: ......
Page 233: ......
Page 241: ......
Page 249: ......
Page 257: ......
Page 265: ......
Page 273: ......
Page 283: ......
Page 293: ......
Page 303: ......
Page 311: ......
Page 321: ......
Page 331: ......
Page 346: ...2WD Hydraulic Schematic First Edition Second Printing Section 6 Schematics...
Page 348: ...4WD Hydraulic Schematic First Edition Second Printing Section 6 Schematics...