Section 3 • Scheduled Maintenance Procedures
January 2012
Part No. 228901
GS-30 • GS-32 • GS-46 • GS-47
3 - 9
Checklist B Procedures
B-1
Inspect the Batteries
Genie requires that this procedure be performed
every 250 hours or quarterly, whichever comes
first.
Proper battery condition is essential to good
machine performance and operational safety.
Improper fluid levels or damaged cables and
connections can result in component damage and
hazardous conditions.
Electrocution/burn hazard. Contact
with electrically charged circuits
could result in death or serious
injury. Remove all rings, watches
and other jewelry.
Bodily injury hazard. Batteries
contain acid. Avoid spilling or
contacting battery acid. Neutralize
battery acid spills with baking soda
and water.
1 Put on protective clothing and eye wear.
2 Release the battery pack latch and rotate the
battery pack out and away from the chassis.
3 Be sure that the battery cable connections are
free of corrosion.
Note: Adding terminal protectors and a corrosion
preventative sealant will help eliminate corrosion
on the battery terminals and cables.
4 Be sure that the battery retainers and cable
connections are tight.
5 Fully charge the batteries. Allow the batteries to
rest 24 hours before performing this procedure
to allow the battery cells to equalize.
Models without maintenance-free or sealed
batteries:
6 Remove the battery vent caps and check the
specific gravity of each battery cell with a
hydrometer. Note the results.
7 Check the ambient air temperature and adjust
the specific gravity reading for each cell as
follows:
•
Add 0.004 to the reading of each cell for
every 10° / 5.5° C above 80° F / 26.7° C.
•
Subtract 0.004 from the reading of each cell for
every 10° / 5.5° C below 80° F / 26.7° C.
Result: All battery cells display an adjusted
specific gravity of 1.277 +/- 0.007. The battery
is fully charged. Proceed to step 11.
Result: One or more battery cells display a
specific gravity of 1.217 or below. Proceed to
step 8.
8 Perform an equalizing charge OR fully charge
the batteries and allow the batteries to rest at
least 6 hours.
9 Remove the battery vent caps and check the
specific gravity of each battery cell with a
hydrometer. Note the results.
Summary of Contents for GC-1530
Page 1: ......
Page 5: ...June 2012 Part No 228901 GS 30 GS 32 GS 46 GS 47 v INTRODUCTION Serial Number Legend...
Page 16: ...June 2012 GS 30 GS 32 GS 46 GS 47 Part No 228901 xvi This page intentionally left blank...
Page 81: ...Section 4 Repair Procedures January 2012 Part No 228901 GS 30 GS 32 GS 46 GS 47 4 19 MANIFOLDS...
Page 83: ...Section 4 Repair Procedures January 2012 Part No 228901 GS 30 GS 32 GS 46 GS 47 4 21 MANIFOLDS...
Page 85: ...Section 4 Repair Procedures January 2012 Part No 228901 GS 30 GS 32 GS 46 GS 47 4 23 MANIFOLDS...
Page 193: ...January 2012 Part No 228901 GS 30 GS 32 GS 46 GS 47 5 11 Section 5 Diagnostics DIAGNOSTICS...
Page 270: ......