Section 4 • Repair Procedures
4 - 118
GS-30 • GS-32 • GS-46 • GS-47
Part No. 228901
SCISSOR COMPONENTS
13 Use the Menu Up or Menu Down buttons to
select No Load calibration.
14 Press the Enter button to select No Load
calibration.
15 Press the Enter button to confirm no load is in
the platform.
16 At the ground controls, press and hold the
Function Enable and Platform Up buttons until
the platform reaches maximum height.
17 When the platform reaches maximum height,
press the ground controls Enter button. Allow
the ground controls to gather data.
18 When prompted, press and hold the
Function Enable and Platform Down buttons
to lower the platform. The platform will move
down, then automatically stop at a
predetermined point to gather data. Allow the
ground controls to gather data.
19 Continue pressing the Function Enable and
Platform Down buttons throughout the lowering
and data gathering sequence. The machine will
stop to gather data and lower several times
before the machine reaches the stowed
position. When the platform reaches the stowed
position, press the Enter button.
20 When prompted, push the red Emergency Stop
button in to complete the No Load Calibration
procedure.
Summary of Contents for GC-1530
Page 1: ......
Page 5: ...June 2012 Part No 228901 GS 30 GS 32 GS 46 GS 47 v INTRODUCTION Serial Number Legend...
Page 16: ...June 2012 GS 30 GS 32 GS 46 GS 47 Part No 228901 xvi This page intentionally left blank...
Page 81: ...Section 4 Repair Procedures January 2012 Part No 228901 GS 30 GS 32 GS 46 GS 47 4 19 MANIFOLDS...
Page 83: ...Section 4 Repair Procedures January 2012 Part No 228901 GS 30 GS 32 GS 46 GS 47 4 21 MANIFOLDS...
Page 85: ...Section 4 Repair Procedures January 2012 Part No 228901 GS 30 GS 32 GS 46 GS 47 4 23 MANIFOLDS...
Page 193: ...January 2012 Part No 228901 GS 30 GS 32 GS 46 GS 47 5 11 Section 5 Diagnostics DIAGNOSTICS...
Page 270: ......