1) Low battery indicator
2) Indicates that the displayed
value is a held reading
3) Measured value
4) Negative polarity indicator
SAFETY INSTRUCTIONS
••
Warning
••
To avoid possible electric shock or personal injury, and to avoid
damaging the meter or the equipment under test:
• Do not use the meter in any way not detailed in this manual or the
meter's safety features may be compromised.
• Before using the meter, inspect the case. Do not use the meter if it is
damaged. Look for cracks or missing plastic. Pay particular attention
to the insulation around the connectors.
•
•
WARNING
Inspect the test leads for damaged insulation or
exposed metal. Check the test leads for continuity. Replace damaged
test leads before using the meter.
• Verify the meter’s operation by measuring a known voltage. Do not
use the meter if it operates abnormally. Protection may be impaired.
When in doubt, have the meter serviced.
•
•
WARNING
Do not apply more than the rated voltage, as marked
on the meter, between the
and
COM
jacks or between any jack
and ground. Also do not input more than the rated current, as
marked on the meter, through the
10A
jack.
•
•
WARNING
Do not measure voltages above 600V in Category II
installations.
•
•
WARNING
Do not attempt to measure voltage with the rotary
function switch in any
or
Ω
position. Never attempt to measure
current with the rotary function switch in any ,
or
Ω
position.
4
Fig. 2. All possible
display indications