7
Form No. 5500-32 Rev C
Code: +0700092EN REV 3.2 04APR2022
ENG
3.4 CHARACTERISTICS OF THE SUPPLY WATER
The humidifier must be supplied with water with the following characteristics:
• Incoming Pressure: Between 20psi and 90psi or 0.1 and 0.8 MPa (1 - 6 bar)
• Maximum intermittent pressure: 110psi (8 bar). Maximum intermittent pressure includes water hammer or other supply water
pressure spikes. High-water pressure can be addressed with water hammer arrestors or pressure regulators.
• Temperature: Between 33°F and 70°F or 1°C and 21°C
• Flow-rate: Minimum of 0.45 L/min or 0.12gpm
• Hardness: No greater than 40°fH (equal to 400 ppm of CaCO3)
• Conductivity: From 125 to 1250 μS/cm using AP-2 (GFI #7066) or similar
• Absence of organic compounds
• The characteristics of the water of supply must fall within the following limits (Table 3.c.)
NORMAL WATER
LOW SALT
CONTENT WATER
UNITS
MIN
MAX
MIN
MAX
Hydrogen ions (pH)
7
8.5
Specific conductivity (R,20°C)
μS/cm
125
1250
Total dissolved solids (c R)
mg/l
(*)
(*)
(*)
(*)
Dry residue at 180°C
mg/l
(*)
(*)
(*)
(*)
Total hardness
mg/l CaC³O
0
200
50
160
Temporary hardness
mg/l CaC³O
=
150
=
200
Iron + Manganese
mg/l Fe + Mn
=
0.2
=
0.2
Chlorides
ppm Cl
=
20
=
30
Chlorides
mg/Si2O
=
20
=
20
Chlorine residue
mg/l Cl-
=
0.2
=
0.2
Calcium sulphate
mg/l CaS4O
=
60
=
100
Tab. 3.c
* Values are dependent on the specific conductivity: cR~=0.65*σR, 20°C; R180~=0.9*σR, 20°C.
NOTE:
There is no relationship between the hardness and conductivity of water.
IMPORTANT:
The following water types are not acceptable:
•
Softened water (will lead to foam, electrode corrosion and greatly shortened cylinder life)
•
Water containing disinfectants or corrosion inhibiters (potential irritants)
•
Industrial water, boiler water or water from cooling circuits
•
Any potentially chemically or bacteriologically-contaminated water
•
Heated water
Summary of Contents for GeneralAire 5500
Page 6: ...6...
Page 37: ...31 Form No 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 ENG...
Page 38: ...32 NOTES...
Page 39: ...33 Form No 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 ENG...
Page 41: ...35 Form No 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 ENG...
Page 42: ...36...
Page 43: ...37 Form No 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 ENG Mode d emploi...
Page 48: ...42...
Page 79: ...31 Formulaire no 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 FRE...
Page 81: ...33 Formulaire no 5500 32 Rev C Code 0700092EN REV 3 2 04APR2022 FRE NOTES...