Application Guidelines
General Application Information
A-2
SpectraComm SDT
076R174-000
Installation and Operation Manual
Issue 4
SC-SDT Configuration Parameters & Defaults
SC-SDT is shipped from the factory with the ordered Default Profile that suits most customer
applications.
lists all configuration parameters, with the Default Configuration Profile #1
settings shown
bold
. Your factory defaults may vary, depending on which profile was ordered
with your unit.
Users can change values from the default setting via Supv or Admin access to the CLI or the web
interface. The Default Profile can be reloaded back into a SC-SDT whenever a “clean baseline” is
desirable prior to downloading a batch file configuration. To accomplish this, type
default all
at the command prompt, or add the
# default all
command uncommented at the start of
your configuration batch file. You may need to reboot the unit.
Table A-1
Configuration Parameters and Defaults
Configurable Option
Description
Parameters and Defaults
System Prompt
Custom prompt
A quoted string; 20 chars max
SDT
CLI Inactivity Timer
Disconnects CLI session after the
desired interval (in secs) has
elapsed.
0 to 10,000 use 0 to disable
900
HTTP Service
HTTP server support for web
management
Enable or
Disable
SNMP Service
SNMP server support for SNMP
management
Enable or
Disable
Telnet Service
Telnet server support for telnet
management
Enable
or Disable
Mgt interface
Set admin state ON (allows xmit &
recv)
Enable or
Disable
Mgt interface IP-address
Defines the management IP
address and mask
IP address (a.b.c.d)
IP mask (a.b.c.d);
Defines the IP broadcast address
(a.b.c.d) (optional)
255.255.255.255
Mgt route add
Defines a static route that adds an
entry to the routing table for a
specific destination IP address or
subnet.
Destination IP network address (a.b.c.d)
Destination IP mask (a.b.c.d)
Destination IP gateway (a.b.c.d)
Metric (1-255)
Mgt default route
Defines a default route that is the
IP address of the next hop when
no other routes are known.
Default router IP address (a.b.c.d)
Mgt route description
Describes the management route
Quoted string; 72 chars max
Contact sense
Configures normal state of contact
Normally open (NO
) or
Normally closed (NC)
Contact sense
Configures the device for contact
sensing.
Enable or
Disable
Contact description
Describes the purpose of contact
(No default)
Port clock invert
Sets xmit clock invert phase
Normal
or Invert
Port clock speed
Sets clock speed and multiplier
Clock speed: 56 or
64
Multiplier:
1
through 32
Port description
Describes the use of the port
A quoted string; 72 chars max
(no default)
Summary of Contents for SpectraComm SDT
Page 73: ......