SC-SDT Configuration
Configuring SC-SDT for Typical Applications
3-4
SpectraComm SDT
076R174-000
Installation and Operation Manual
Issue 4
Configuring SC-SDT for Typical Applications
The following procedure configures the SC-SDT for a typical deployment in your network as a sync
data transport device. Before configuring the SC-SDT, ensure that the device has already been
initialized as described in the previous section:
Initializing the SC-SDT for Configuration
Note
Some ADMIN mode configuration commands (i.e., enabling the craft port or setting up user accounts)
cannot be accessed or executed via the web interface.
Note
In the configuration sample below, [brackets] indicate user-defined entries or typical entries. For the default
of any configuration setting, use the online help or refer to the listing in Appendix A, Application Guidelines .
Basic Configuration
Management Configuration Settings
The first three steps of this procedure are required in order to configure the SC-SDT for
management. You must change the SC-SDT from its default settings, as shown. Throughout this
procedure you can type
?
following any command, sub-command or parameter for context-
sensitive online help.
1. Configure the HTTP Service to enable access by typing:
services http enable
2. Configure the SNMP Service to enable access by typing:
services snmp enable
3. If desired, enable management access via ethernet (the default setting) by typing:
services telnet enable
Optional Configuration Settings
The remaining steps use default values pre-loaded in the SC-SDT unit. If the default value applies
to your network, you do not need to re-enter it. Otherwise, enter the value that best suits your
network environment. Type
?
following any command, sub-command or parameter for context-
sensitive online help.
4. Set the system prompt by typing:
configure prompt
[SC-SDT]
5. Configure the Inactivity Timer to disconnect a management session after the desired interval
(in seconds) has elapsed. Range is 0 - 10,000 sec, where 0 disables the timer.
configure inactivity
[900]
Summary of Contents for SpectraComm SDT
Page 73: ......