background image

Installation & Connections

Overview

076R174-000

SpectraComm SDT  

2-13

Issue 4

Installation and Operation Manual

Note

The 26-pin connector pins 14, 15, 16, 19, 23, 24 and 26 are connected together.

Table 2-9

EIA/TIA-232 DTE Serial Cable Pinouts

26-pin

Signal Name

Note

Direction

DB25-pin

Signal Name

23
24

MODE_0

MODE_DCE

1

14

TXD/RXD+

GND+

Twisted

Pair

-->

---

2
7

TXD

GND

2

15

TXC/RXC+

GND+

Twisted

Pair

-->

---

24

7

TXCE

GND

3

16

TXC/TXC+

GND+

Twisted

Pair

<--

---

15

7

TXC

GND

4

RXC/TXC+

<--

17

RXC

5

RXD/TXD+

<--

3

RXD

6

19

DCD/DCD+

GND+

Twisted

Pair

<--

---

8
7

DCD
GND

7
8

DTR/DSR+

RTS/CTS+

Twisted

Pair

-->
-->

20

4

DTR

RTS

11
12

CTS/RTS+

DSR/DTR+

Twisted

Pair

<--
<--

5
6

CTS

DSR

13
26

LL/LL+

GND+

Twisted

Pair

-->

---

18

7

LTST

GND

Shell

Drain Wire Shield

Pin 1 to Shell

Shield_GND

Summary of Contents for SpectraComm SDT

Page 1: ...The Best Connections in the Business General DataComm 6SHFWUD RPP 6 7 Synchronous Data Transport Installation Operation Manual 076R174 000 Issue 4 May 2012...

Page 2: ...Telephone 1 203 729 0271 Trademarks All brand or product names are trademarks or registered trademarks of their respective companies or organizations Documentation Revision History GDC P N 076R174 00...

Page 3: ...agement 1 4 SC SDT Front Panel Interface 1 5 SC SDT Applications Overview 1 6 A Transport Applications 1 7 A Contact Sense Applications 1 8 Technical Specifications 1 9 Chapter 2 Installation Connecti...

Page 4: ...w of Additional Features 5 1 Time Protocols 5 1 TACACS Authentication Protocol 5 2 Contact Sense 5 6 Monitoring Features 5 8 System Message Log 5 8 Alarm Log 5 8 Management Status Statistics 5 9 Port...

Page 5: ...ided into the following chapters When using the digital version of this manual click on any link shown in blue text to jump to that section Chapter 1 Introduction Specifications describes the SpectraC...

Page 6: ...telephone wiring during an electrical storm Antistatic Precautions This product may contain static sensitive devices that are easily damaged by ESD electrostatic discharge ESD occurs when a person who...

Page 7: ...2 This device must accept any interference received including interference that may cause undesired operation Electromagnetic Compatibility This Class A digital apparatus complies with FCC Part 15 an...

Page 8: ...upport Repair GDC provides regular and warranty repair services through Factory Direct Support Repair at its U S headquarters in Naugatuck Connecticut This customer support organization repairs and re...

Page 9: ...M ALM DTR OH NR ND ADV ST SC ES 18 PORT ETHERNET SWITCH 8 7 6 5 4 3 2 1 17 16 15 15 13 12 11 10 9 ON 18 SCM CTRL SD RD SD RD NR ND TM ALM INS ON L A N W A N V F 28 8 LL RL DL SEL TXD RXD RTS CTS DCD G...

Page 10: ...cable connections High performance run from ram architecture includes a running version a primary version and standby version of software Provides a DB25 connector for Contact Sense and as a console p...

Page 11: ...e for packetized HDLC based synchronized data transport Six serial interfaces are supported EIA TIA 232 EIA TIA 449 X 21 and V 35 in both DTE and DCE modes and EIA530 or EIA530A in DTE mode only Diagn...

Page 12: ...ess to the SC SDT using popular browsers To enhance security the SC SDT supports web time outs and password protected access over the web interface HTTP services can also be disabled to block web acce...

Page 13: ...es the associated ethernet link is up LED OFF indicates the associated ethernet link is down Flashing GREEN indicates the associated ethernet link is receiving transmitting data PORTS 1 3 Steady GREEN...

Page 14: ...he device alarm transfer between locations will be supported Figure 1 2 shows the SC SDT at remote sites supporting multiple applications simultaneously Each application is detailed in the pages that...

Page 15: ...ort will receive clocking from the local equipment A DCE type port will provide clocking to the local equipment Figure 1 3 shows multiple sites with sync equipment linked together over the customer s...

Page 16: ...a remote SC SDT device to open or close a relay at that site SC SDT devices will be required at both sites Trap and Transport Future option The alarm will be transported between sites and a Trap will...

Page 17: ...ps Environment Non Operating Temperature 40 to 70 degrees C 40 to 158 degrees F Relative Humidity 5 to 95 Altitude up to 12 191 m 40 000 ft Operating Temperature 0 to 50 degrees C 32 to 122 degrees F...

Page 18: ...Introduction Specifications Technical Specifications 1 10 SpectraComm SDT 076R174 000 Installation and Operation Manual Issue 4...

Page 19: ...tall the shelf directly above equipment such as power supplies which generate large amounts of heat When SC SDT devices are to be installed in the SC 2000 shelf do not wall mount the shelf vertically...

Page 20: ...SDT rackmount 10 100Base T Ethernet 076P048 001 SC SDT in RA1000 AC standalone enclosure 100 to 240VAC 10 100Base T Ethernet 076A048 001 SC SDT in SC1002 DC standalone enclosure 24 48 VDC 10 100Base...

Page 21: ...pply 010B226 002 SpectraComm 16 Slot Shelves MS 2 Model 1 includes two 8 slot dual RJ45 Zone 1 connector panels 100 120 VAC 010M054 001 MS 2 Model 2 includes two 8 slot dual RJ45 Zone 1 connector pane...

Page 22: ...e whether the SC SDT can be powered from the same AC circuit as the equipment connected to its ports Having the SC SDT and the connecting equipment on the same AC circuit prevents large circulating cu...

Page 23: ...J22 J38 J21 J37 J20 J36 J19 J35 J18 J34 J17 J33 J52 J14 J12 J11 J16 J15 J13 J10 J9 J8 J7 J6 J5 J2 J1 J4 J3 J51 J50 CONNECTOR DETAILS ETHERNET LAN PORT B A NOT USED B D B A SC SDT CONNECTIVITY PIN 1 CR...

Page 24: ...net connectivity and requires RJ45 to RJ45 straight thru or crossover cables GDC S 078H010 XXX or S 078H011 XXX The table below describes Ethernet port pinouts Note that the Ethernet port can be used...

Page 25: ...ata Supervisory data from the terminal 3 Craft Out From SC SDT Receive Data Supervisory data to the terminal 7 Craft GND Signal ground for craft interface Contact Sense 5 Out 1 GND Output GND for cont...

Page 26: ...DTE mode and DCE mode EIA530 in DTE mode and EIA530A in DTE mode Each smart cable connects to the SC SDT via a 26 pin connector The following figure and tables describe the pinouts for each interface...

Page 27: ...24 MODE_1 MODE_0 MODE_DCE 1 14 TXD RXD TXD RXD Twisted Pair P S SD SD 2 15 TXCE RXC TXCE RXC Twisted Pair U W SCTE SCTE 3 16 TXC TXC TXC TXC Twisted Pair Y AA SCT SCT 4 17 RXC TXCE RXC TXCE Twisted Pa...

Page 28: ...2 23 MODE_1 MODE_0 1 14 TXD RXD TXD RXD Twisted Pair R T RD RD 2 15 TXCE RXC TXCE RXC Twisted Pair V X SCR SCR 3 16 TXC TXC TXC TXC Twisted Pair Y AA SCT SCT 4 17 RXC TXCE RXC TXCE Twisted Pair U W SC...

Page 29: ...D RXD Twisted Pair 4 22 SD SD 2 15 TXCE RXC TXCE RXC Twisted Pair 17 35 TT TT 3 16 TXC TXC TXC TXC Twisted Pair 5 23 ST ST 4 17 RXC TXCE RXC TXCE Twisted Pair 8 26 RT RT 5 18 RXD TXD RXD TXD Twisted P...

Page 30: ...XD Twisted Pair 6 24 RD RD 2 15 TXCE RXC TXCE RXC Twisted Pair 8 26 RT RT 3 16 TXC TXC TXC TXC Twisted Pair 5 23 ST ST 4 17 RXC TXCE RXC TXCE Twisted Pair 17 35 TT TT 5 18 RXD TXD RXD TXD Twisted Pair...

Page 31: ...me Note Direction DB25 pin Signal Name 23 24 MODE_0 MODE_DCE 1 14 TXD RXD GND Twisted Pair 2 7 TXD GND 2 15 TXC RXC GND Twisted Pair 24 7 TXCE GND 3 16 TXC TXC GND Twisted Pair 15 7 TXC GND 4 RXC TXC...

Page 32: ...al Name Note Direction DB25 pin Signal Name 23 MODE_0 1 14 TXD RXD GND Twisted Pair 3 7 RXD GND 2 15 TXC RXC GND Twisted Pair 17 7 RXC GND 3 16 TXC TXC GND Twisted Pair 15 7 TXC GND 4 RXC TXC 24 TXCE...

Page 33: ...Twisted Pair 24 11 DB A TXCE DB B TXCE 3 16 TXC TXC TXC TXC Twisted Pair 15 12 DB A TXC DB B TXC 4 17 RXC TXCE RXC TXCE Twisted Pair 17 9 DD A RXC DD B RXC 5 18 RXD TXD RXD TXD Twisted Pair 3 16 BB A...

Page 34: ...wisted Pair 24 11 DB A TXCE DB B TXCE 3 16 TXC TXC TXC TXC Twisted Pair 15 12 DB A TXC DB B TXC 4 17 RXC TXCE RXC TXCE Twisted Pair 17 9 DD A RXC DD B RXC 5 18 RXD TXD RXD TXD Twisted Pair 3 16 BB A R...

Page 35: ...n Signal Name Note Direction DB15 pin Signal Name 21 24 MODE_2 MODE_DCE 1 14 TXD RXD TXD RXD Twisted Pair 2 9 TRANSMIT TRANSMIT 4 17 RXC TXCE RXC TXCE Twisted Pair 6 13 TIMING TIMING 5 18 RXD TXD RXD...

Page 36: ...26 pin Signal Name Note Direction DB15 pin Signal Name 21 MODE_2 1 14 TXD RXD TXD RXD Twisted Pair 4 11 RECEIVE RECEIVE 2 15 TXCE RXC TXCE RXC Twisted Pair 6 13 TIMING TIMING 5 18 RXD TXD RXD TXD Twis...

Page 37: ...and string Type at the command prompt to view a description of IP and Utility commands shown below If you are in User mode some commands shown below will not display _______________________System Comm...

Page 38: ...get help SC SDT Note For online help screens describing all CLI options press Note that the CLI options for configuring the SC SDT are only available when you have enabled Supervisor or Admin privileg...

Page 39: ...cess plus the ability to set up and modify user accounts for usernames and passwords ADMIN mode also allows authentication for the CRAFT port to be turned on or off Note Some ADMIN mode configuration...

Page 40: ...e steps of this procedure are required in order to configure the SC SDT for management You must change the SC SDT from its default settings as shown Throughout this procedure you can type following an...

Page 41: ...name configure snmp system contact your system contact configure snmp system location your system location Creating a Login Banner SC SDT is shipped from the factory with no Login banner When you com...

Page 42: ...acter 5 At the prompt enter your login message maximum 30 lines 80 characters per line 6 When your message is completed type your escape character or press Ctrl C 7 To view your new login banner type...

Page 43: ...ch SC SDT device to verify IP connectivity 6 Cable up the both SC SDT devices using the appropriate smart serial interface cable for your application When the smart serial cable selected for your netw...

Page 44: ...10 Enable each configured sync port to receive and transmit sync data in approximately 20 seconds by typing configure ports enable port n or all For example configure ports enable all Note The ports e...

Page 45: ...onally disabling the link See Chapter 5 Additional Features for information on the Call Hello function 2 Disable the port to be reconfigured by typing configure ports disable port n or all 3 Clear the...

Page 46: ...SC SDT Configuration Configuring SC SDT for Typical Applications 3 10 SpectraCommSDT 076R174 000 Installation and Operation Manual Issue 4...

Page 47: ...gh 5 x are supported Internet Explorer 5 0 or higher Cookies must be enabled Note At the terminal or craft interface you can toggle http disable enable to clear all cookies 2 Via the Telnet or the Cra...

Page 48: ...privileges as assigned by an Administrator A valid password can be up to 20 alphanumeric characters If three consecutive invalid passwords are entered a temporary lock out will occur Access Modes Acce...

Page 49: ...st logout of the web interface and make a Telnet or terminal connection in ADMIN mode to access execute those commands Table 4 1 Command Line Web Screen Field Description clear Displays a selectable l...

Page 50: ...The Web Interface Introduction to Web Management 4 4 SpectraComm SDT 076R174 000 Installation and Operation Manual Issue 4...

Page 51: ...nwich Mean Time GMT to timestamp the SNMP traps System Messages and Alarms when they are generated When neither SNTP nor TP is configured the SC SDT will use a relative System Up Time for timestamping...

Page 52: ...TACACS server When TACACS is enabled the TACACS server becomes the central point for managing network wide usernames and passwords This is especially useful when provisioning SC SDT devices in large n...

Page 53: ...onsiderations for using TACACS authentication listed at the end of this section Note You must log in with ADMIN privileges to execute the commands in this procedure 1 At the prompt type enable 2 Type...

Page 54: ...r type configure tacacs banner tacacs description configure tacacs banner local description TACACS Verification Procedure When a SC SDT device is enabled for TACACS authentication it is highly recomme...

Page 55: ...typing L 4 Use the default passwords to reconfigure the SC SDT from scratch TACACS Special Considerations In order to change local authentication configuration values or enable and configure TACACS au...

Page 56: ...Contact Sense for all ports simultaneously Each contact port must be configured as Normally Opened or Normally Closed A closed condition on a normally opened port will cause an ACTIVE condition Likewi...

Page 57: ...enter an alphanumeric description of the contact port by typing configure contact description c contact description Note If a space is desirable in the description you must use a double quoted string...

Page 58: ...the last 100 SYS MSG events saved to the log Use this log to examine link status diagnostic test activity etc The System Message log is not saved when the unit reboots To show the last 100 logged even...

Page 59: ...076R174 000 SpectraCommSDT 5 9 Issue 4 Installation and Operation Manual Management Status Statistics To show management status and statistics type the following command show mgt Figure 5 5 Typical D...

Page 60: ...00 Installation and Operation Manual Issue 4 Port Status and Statistics To show port status type the following command show ports tport To show port statistics type the following command show ports st...

Page 61: ...unicate via plain text in a separate window This feature is useful in informing a connected CLI user of pending configuration or software maintenance on the SC SDT which may interrupt port or device a...

Page 62: ...d trap is sent Each SNMP trap is time stamped with a relative System Up Time default or with GMT if so configured refer to Time Protocols in this chapter SNMP Trap Configuration To configure SC SDT to...

Page 63: ...or cannot be used as username logins They are only used to enable the supervisor admin mode The only default username login is defined as gdc with the password gdc This username may be deleted or its...

Page 64: ...TP Service HTTP server support for web management Enable or Disable SNMP Service SNMP server support for SNMP management Enable or Disable Telnet Service Telnet server support for telnet management En...

Page 65: ...oted string 128 chars max YOUR SYSTEM NAME SNMP system contact Identifies the contact person for the managed node adn the method of contact A quoted string 128 chars max YOUR SYSTEM CONTACT SNMP syste...

Page 66: ...spond before trying the next server on the list 1 to 10 seconds 5 Configure Time Controls the use of Simple Network Time Protocol RFC2030 and Time Protocol RFC 868 Enable or Disable Note When configur...

Page 67: ...g of a command line the screen displays all the commands available along with a one line description of each command SDT _______________________System Commands___________________________ clear Reset f...

Page 68: ...ires 1 parameter s banner Configure login banner contact Configure contact sense parameters inactivity Configure CLI inactivity timer requires 1 parameter s mgt Configure management parameters ports C...

Page 69: ...s executed by pressing the Enter key or cr The general syntax is command subcommand s if any required argument s if any Aborting a Command Use the CTRL C character to abort a command at any time and r...

Page 70: ...HyperTerminal at the CTRL interface Users can initially setup the SC SDT from a predefined configuration file rather than entering one command at a time Special Considerations for Batch Files You must...

Page 71: ...SC SDT if using IP Addressing on a sub interface IP Address for the SC SDT in the network manager not correct Cables not installed 1 At the command prompt type show mgt to check that the ethernet0 in...

Page 72: ...Application Guidelines Troubleshooting Communications Problems A 10 SpectraComm SDT 076R174 000 Installation and Operation Manual Issue 4...

Page 73: ......

Page 74: ...The Best Connections in the Business...

Reviews: