Rev. 01 08/20
OptiStar All-in-One (CG22-C)
Start-up
31
No.
Description
Values
Display
P05
CAN Baud rate
0: 20 kbit/s
1: 50 kbit/s
2: 100 kbit/s
3:
125 kbit/s
4: 250 kbit/s
5: 500 kbit/s
6: 800 kbit/s
7: 1 Mbit/s
20k
50k
100k
125k
250k
500k
800k
1M
P06
CAN Node ID
1
-127
P07
Air mode
(Air volume setting)
0:
Standard (PA / GL)
1: Advanced (FL / ZL)
Standard
Advanced
P08
Remote change
(Procedure when changing
Local / Remote)
0:
Gun release is reset
Turn gun off
1: Gun release is not changed
Keep gun state
2: Gun release always active
Always enabled
P10
Log level
0, 1,
2
, 3, 4, 5
P11
BLE Devid
(Bluetooth ID no.)
0: Bluetooth deactivated
1
- 255
P12
Rmt Ctrl
(Remote control)
0:
Powder /-
Cleaning activation
1 : Program change
Cleaning activation
PA / Clean
Prog / Clean
1)
is not overwritten, if a Memory Reset is performed
Default values are marked by
bold
print.
5.
Scroll to the next or previous system parameter with the
or
key
Selection is cyclical, i.e. after the last system parameter, the first
starts again and vice versa.
6.
Press
key to quit the system parameter mode.
– The display switches to the
START
screen
Summary of Contents for CG22-C
Page 6: ......
Page 28: ...Rev 01 08 20 28 Assembly Connection OptiStar All in One CG22 C ...
Page 36: ...Rev 01 08 20 36 Start up OptiStar All in One CG22 C ...
Page 50: ...Rev 01 08 20 50 Operation OptiStar All in One CG22 C ...
Page 54: ...Rev 01 08 20 54 Maintenance Repairs OptiStar All in One CG22 C ...
Page 60: ...Rev 01 08 20 60 Disposal OptiStar All in One CG22 C ...
Page 65: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 65 Powder conveying unit fig 16 ...
Page 67: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 67 Valve block fig 17 ...
Page 69: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 69 Connecting material fig 18 ...
Page 70: ......
Page 72: ...Rev 01 08 20 72 Index OptiStar All in One CG22 C ...
Page 73: ......
Page 74: ...Rev 01 ...