Fault clearance
OptiStar All-in-One (CG22-C)
Code
Description
Criteria
Remedy
H08
Conveying air volume too
high (setting of powder
share on the display)
The preset value for conveying
air is too high compared to the
supplementary air setting
Lower conveying air value
or increase value for
supplementary air to
equalize air volumes to the
injector, delete error code
H09
Powder output higher
than 100%
The powder output multiplied by
the powder hose length factor
and daily correction value is
greater than 100%
Daily correction value too large
Reduce powder output
Reduce daily correction
value
H10
Conveying air range
lower deviation
The theoretical value for
conveying air falls below
minimum
Total air is smaller than minimum
Limit conveying air to its
minimum value
High voltage:
H11
Gun error
No vibrations in the oscillator,
cable break, oscillator or gun is
defective
Contact a Gema service
center
H13
Gun Overload
Cable or cascade defective. The
control unit is switched off.
Contact a Gema service
center
Power supply:
H20
Voltage supply error
Mainboard
Mainboard defective
Contact a Gema service
center
H21
Supply undervoltage
Power pack defective or
overloaded
Contact a Gema service
center
H22
Wrong internal system
clock
Backup battery is empty
Contact Gema Service
EEPROM (equipment memory):
H24
EEPROM content invalid
EEPROM error
Contact Gema Service
H25
Timeout during EEPROM
writing
EEPROM error
Contact Gema Service
H26
Values not correctly
stored in EEPROM during
switching off
EEPROM error
Contact Gema Service
H27
EEPROM verification
erroneous
EEPROM error
Contact Gema Service
CAN bus:
H40
Permanent CAN bus error
The CAN controller changes into
BUS OFF condition.
No power supply or cable is not
connected.
Connect the cable,
otherwise contact Gema
service
H41
High error rate when
transmitting/receiving
The CAN controller changes into
ERROR_PASSIVE condition
Contact a Gema service
center
H42
Overflow on data
reception
The message to be received has
no more place in the receiver
buffer. Messages are sent faster
than they can be processed.
Contact a Gema service
center
Summary of Contents for CG22-C
Page 6: ......
Page 28: ...Rev 01 08 20 28 Assembly Connection OptiStar All in One CG22 C ...
Page 36: ...Rev 01 08 20 36 Start up OptiStar All in One CG22 C ...
Page 50: ...Rev 01 08 20 50 Operation OptiStar All in One CG22 C ...
Page 54: ...Rev 01 08 20 54 Maintenance Repairs OptiStar All in One CG22 C ...
Page 60: ...Rev 01 08 20 60 Disposal OptiStar All in One CG22 C ...
Page 65: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 65 Powder conveying unit fig 16 ...
Page 67: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 67 Valve block fig 17 ...
Page 69: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 69 Connecting material fig 18 ...
Page 70: ......
Page 72: ...Rev 01 08 20 72 Index OptiStar All in One CG22 C ...
Page 73: ......
Page 74: ...Rev 01 ...