OptiStar All-in-One (CG22-C)
Fault clearance
57
Code
Description
Criteria
Remedy
H43
Overflow on transmission
The message to be sent has no
more place in the transmission
buffer. Messages are produced
faster than they can be sent.
Contact a Gema service
center
H44
Master failed
Node Guarding message is
missing longer than 2 seconds.
Connection to master failed.
Check the connection to
the Master, otherwise
contact Gema service
H45
Parameter value outside
the value range
The sent parameter value is
outside the allowed value range
Check input values
H46
Invalid Node ID set
The Node ID is not between 1
and 127
Set Node ID to 127
H47
No CAN interface
installed
CAN interface is selected in the
system parameters, but no
interface is installed
Contact Gema Service
H48
No ACK to "Boot Up
Message" received
No CAN node is answering to
the "Boot Up Message".
Check cabling connections
between the users,
otherwise contact Gema
service
Pneumatics 2:
H50
Suction section clogged
Negative pressure on suction
side too high
Check the suction section,
otherwise adjust the
correction value C4
H51
Powder hose to the gun
bent or clogged
No negative pressure on suction
side present
Check the powder hose
H52
Pinch valve
Solenoid coil current lower than
preset limiting value
Valve defective, main board or
cable defective
Contact a Gema service
center
H53
Cleaning solenoid valve
(suction side)
Solenoid coil current lower than
preset limiting value
Valve defective, main board or
cable defective
Contact a Gema service
center
H54
Cleaning solenoid valve
(blow-off side)
Solenoid coil current lower than
preset limiting value
Valve defective, main board or
cable defective
Contact a Gema service
center
Throttle motors:
H60
Conveying air reference
position not found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact a Gema service
center
H61
Supplementary air
reference position not
found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact a Gema service
center
H62
Electrode rinsing air
reference position not
found
Throttle motor or needle
jammed, limit switch defective,
error in motor throttle
Contact a Gema service
center
H64
Conveying air throttle
does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H65
Supplementary air throttle
does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
Summary of Contents for CG22-C
Page 6: ......
Page 28: ...Rev 01 08 20 28 Assembly Connection OptiStar All in One CG22 C ...
Page 36: ...Rev 01 08 20 36 Start up OptiStar All in One CG22 C ...
Page 50: ...Rev 01 08 20 50 Operation OptiStar All in One CG22 C ...
Page 54: ...Rev 01 08 20 54 Maintenance Repairs OptiStar All in One CG22 C ...
Page 60: ...Rev 01 08 20 60 Disposal OptiStar All in One CG22 C ...
Page 65: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 65 Powder conveying unit fig 16 ...
Page 67: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 67 Valve block fig 17 ...
Page 69: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 69 Connecting material fig 18 ...
Page 70: ......
Page 72: ...Rev 01 08 20 72 Index OptiStar All in One CG22 C ...
Page 73: ......
Page 74: ...Rev 01 ...