Rev. 01 08/20
OptiStar All-in-One (CG22-C)
Operation
45
3.
Switch off the gun after 60 seconds, remove the measuring bag and
weigh it
4.
Annotate the powder output in
g/min
in the table
Calculate the powder output correction according to following formula:
C1 (%) =
smallest powder output
x 100
measured powder output
5.
Annotate the calculated values (
C1
) for each individual gun in the
table and enter the values to the control unit (therefore, repeat the
steps 2 and 3)
Example table for powder offset and powder hose
correction
Gun
Powder offset correction C0
No.
Before
correction
After
correction
1
C0=1.8 Nm³/h
20 g
C0=1.7 Nm³/h
12 g
2
C0=1.8 Nm³/h
10 g
C0=1.8 Nm³/h
13 g
3
C0=1.8 Nm³/h
0 g
C0=2.6 Nm³/h
12 g
etc.
Gun
Powder hose correction C1
No.
Before
correction
After
correction
1
C1=100 %
200 g
C1=100 %
200 g
2
C1=100 %
250 g
C1=80%
200 g
3
C1=100 %
280 g
C1=71%
200 g
etc.
Summary of Contents for CG22-C
Page 6: ......
Page 28: ...Rev 01 08 20 28 Assembly Connection OptiStar All in One CG22 C ...
Page 36: ...Rev 01 08 20 36 Start up OptiStar All in One CG22 C ...
Page 50: ...Rev 01 08 20 50 Operation OptiStar All in One CG22 C ...
Page 54: ...Rev 01 08 20 54 Maintenance Repairs OptiStar All in One CG22 C ...
Page 60: ...Rev 01 08 20 60 Disposal OptiStar All in One CG22 C ...
Page 65: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 65 Powder conveying unit fig 16 ...
Page 67: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 67 Valve block fig 17 ...
Page 69: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 69 Connecting material fig 18 ...
Page 70: ......
Page 72: ...Rev 01 08 20 72 Index OptiStar All in One CG22 C ...
Page 73: ......
Page 74: ...Rev 01 ...