Rev. 01 08/20
30
Start-up
OptiStar All-in-One (CG22-C)
3.
Set the corresponding system parameter value with the
or
key.
4.
Select parameter values according to the following table
No.
Description
Values
Display
P00
1)
Application
(Device type)
3:
Automatic device (CG22-C)
C
P02
Pressure
(Input pressure)
0: P in = 5.5 bar
1:
P in = 6 bar
2: P in = 6.5 bar
5.5
6.0
6.5
P03
Air unit
(air measurement unit)
0:
Nm³/h
1: scfm
m³/h
SCFM
P04
Bus interface
(Interface type)
0: Deactivated
1:
Automatic recognition
OFF
Auto