Rev. 01 08/20
58
Fault clearance
OptiStar All-in-One (CG22-C)
Code
Description
Criteria
Remedy
H66
Electrode rinsing air
throttle does not move
Short circuit in limit switch, motor
throttle defective
Contact a Gema service
center
H68
Conveying air position
lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
H69
Supplementary air
position lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
H70
Electrode rinsing air
position lost
Lost steps, limit switch defective,
throttle motor defective
Contact a Gema service
center
Communication mainboard-gun:
H91
Communication error
mainboard-gun
Gun, gun cable or Mainboard
defective
Replace or contact Gema
Service
Help codes list
The last appeared four errors are stored in a list by the software. If an
error appears, which is already in the list, he will not be listed again.
Appearance of errors
It is possible that an error is only displayed for a short time, but after the
acknowledgement it will disappear. In this case, it's recommended to
switch off the control unit and switch it on again (reset by restarting).
Summary of Contents for CG22-C
Page 6: ......
Page 28: ...Rev 01 08 20 28 Assembly Connection OptiStar All in One CG22 C ...
Page 36: ...Rev 01 08 20 36 Start up OptiStar All in One CG22 C ...
Page 50: ...Rev 01 08 20 50 Operation OptiStar All in One CG22 C ...
Page 54: ...Rev 01 08 20 54 Maintenance Repairs OptiStar All in One CG22 C ...
Page 60: ...Rev 01 08 20 60 Disposal OptiStar All in One CG22 C ...
Page 65: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 65 Powder conveying unit fig 16 ...
Page 67: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 67 Valve block fig 17 ...
Page 69: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 69 Connecting material fig 18 ...
Page 70: ......
Page 72: ...Rev 01 08 20 72 Index OptiStar All in One CG22 C ...
Page 73: ......
Page 74: ...Rev 01 ...