OptiStar All-in-One (CG22-C)
Operation
43
4.
Select correction values according to the following table
Corr.
value
Description
Range
Default
value
C0
Powder offset (Nm³/h)
0.5 -3.0
1.8
C1
Powder hose correction value (%)
40-100
100
C2
Daily correction value (%)
50-150
100
C4
Threshold value Suction section clogged (mbar)
-
200…-5
-70
C5
Threshold value Powder hose clogged (mbar)
30…70
50
5.
Scroll to the next or previous correction value with the
or
key
Selection is cyclical, i.e. after the last correction value, the first
starts again and vice versa.
6.
Press
key to quit the correction values mode.
– The display switches to the
START
screen