83
80415F_MSW_GFX4-IR_05-2019_ENG
SELFTUNING
31
s.tv
R/W
Enable selftuning,
autotuning, softstart
140
diG.
R/W
Digital input function
618
diG.2
R/W
Digital input function 2
3
bit
SELFTUNING
OFF = Stop Selftuning
ON = Start selftuning
R/W
305
R/W
Instrument state
(STATUS_W)
68
bit
DIGITAL INPUT
STATE 1
OFF = Digital input 1 off
ON = Digital input 1 on
R
92
bit
DIGITAL INPUT
STATE 2
OFF = Digital input 2 off
ON = Digital input 2 on
R
0
bit
SELFTUNING STATE
OFF = Selftuning in Stop
ON = Selftuning in Start
R
296
R
Enable autotuning and selftuning state
(FLG_PID)
SOFTSTART
31
s.tv
R/W
Enable selftuning,
autotuning, softstart
147
SOF
R/W
Softstart time
63
bit
SOFTSTART STATE
OFF = Softstart in Stop
ON = Softstart in Start
R
140
diG.
R/W
Digital input function
618
diG.2
R/W
Digital input function 2
11
bit
SOFTWARE ON/OFF
OFF = On
ON =Off
R/W
305
R/W
Instrument state
(STATUS_W)
SOFTWARE SHUTDOWN
68
bit
DIGITAL INPUT
STATE 1
OFF = Digital input 1 off
ON = Digital input 1 on
R
92
bit
DIGITAL INPUT
STATE 2
OFF = Digital input 2 off
ON = Digital input 2 on
R
FAULT ACTION POWER
265
xot
R/W
Select hot runner functions
228
fa.p
R/W
Fault action power
(supplied in conditions of broken probe)
26
bit
STATE OF HB ALARM
OR POWER_FAULT
OFF = Alarm off
ON = Alarm on
R
80
State of power alarm
(hot runners)
OFF = Alarm off
ON = Alarm on
R
699
P.ONT
R/W
Start mode at Power-On
START MODE
30
bit
RESTART
SOFTSTART
OFF = -
ON = Restartl Softstart
R/W