132
AFE200 • Instruction Manual
indicates the end of pre-loading. It is used to close the main contactor and open the
pre-load resistor contactor.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
-
1210 Digital input 1X mon
BIT
16BIT
0
0
1
ER
-
1212 Digital input 2X mon
BIT
16BIT
0
0
1
ER
-
1214 Digital input 3X mon
BIT
16BIT
0
0
1
ER
-
1216 Digital input 4X mon
BIT
16BIT
0
0
1
ER
-
1218 Digital input 5X mon
BIT
16BIT
0
0
1
ER
-
1220 Digital input 6X mon
BIT
16BIT
0
0
1
ER
-
1222 Digital input 7X mon
BIT
16BIT
0
0
1
ER
-
1224 Digital input 8X mon
BIT
16BIT
0
0
1
ER
These signals represent the state of the corresponding digital input on the expansion card.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
-
1530 Analog inp1
BIT
16BIT
0
0
1
ER
This signal is active when the value of the analog input is below the threshold set in
parameter
1520 Analog inp 1 thr
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
-
1580 Analog inp2
BIT
16BIT
0
0
1
ER
This signal is active when the value of the analog input is below the threshold set in
parameter
1570 Analog inp 2 thr
.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
-
2388 Active curr noflt
A
FLOAT
16BIT
0.0
0.0
0.0
ER
The active current reference is displayed without filter.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
-
3260 Bres overload accum
perc
UINT16 16BIT
0
0
100
ER
The braking resistor overload limit is displayed (100% = alarm threshold). This param-
eter is not available for the standard version of the AFE200..
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
-
4708 Alm dig out mon 1
BIT
16BIT
0
0
1
ER
This signal is activated when the alarm configured in parameter
4700 alarm dig sel 1
is active.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
-
4710 Alm dig out mon 2
BIT
16BIT
0
0
1
ER
This signal is activated when the alarm configured in parameter
4702 alarm dig sel 2
is active.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
-
4712 Alm dig out mon 3
BIT
16BIT
0
0
1
ER