page | 66
Commands
Internal EDID (#SET_ / #GET_)
Download a preset Internal EDID.
Syntax
#SET_EDID_MODE PARAM1 PARAM2
Parameters
PARAM1 = 1 ~ 4, 0
1 ~ 4 - HDMI INPUTS
0 - ALL HDMI INPUTS (FEEDBACK LISTS ALL INPUTS IN
ORDER 1 ~ 4)
PARAM2 = 1 ~ 4
1 - INTERNAL - 720P 2 CH
2 - INTERNAL - 1080P 2 CH
3 - EXTERNAL (BYPASS MODE)
4 - CUSTOM MODE - USER
Examples
#SET_EDID_MODE 1 1
#SET_EDID_MODE 0 1
Get Input EDID mode.
Syntax
#GET_EDID_MODE PARAM1
Parameters
PARAM1 = 1 ~ 4, 0
1 ~ 4 - HDMI INPUTS
0 - ALL HDMI INPUTS (FEEDBACK LISTS ALL INPUTS IN
ORDER 1 ~ 4)
Examples
#GET_EDID_MODE 1
#GET_EDID_MODE 0\
IO Name (#SET_ / #GET_)
Modify the name of an input or window.
Syntax
#SET_IO_NAME PARAM1 PARAM2
Parameters
PARAM1 = 1 ~ 4, A ~ D
1 ~ 4 - HDMI INPUTS
A ~ D - WINDOWS
PARAM2 = 1 ~ 12 ALPHANUMERIC CHARACTERS
ALLOWED CHARACTERS = A-Z, a-z, 0-9, and spaces (NO
SPECIAL CHARACTERS)
Examples
#SET_IO_NAME 1 BLURAY
#SET_IO_NAME A WINDOW 1
Get the name of an input or output.
Syntax
#GET_IO_NAME PARAM1
Parameters
PARAM1 = 1 ~ 4, A ~ D
1 ~ 4 - HDMI INPUTS
A ~ D - WINDOWS
Examples
#GET_IO_NAME 1
#GET_IO_NAME A
Summary of Contents for 4x1 Multiview Seamless Switcher
Page 10: ......
Page 11: ...01 Getting Started Multiview Seamless Switcher...
Page 14: ...page 4 IR Remote Control Unit 4 3 2 8 6 10 12 11 7 5 9 1...
Page 20: ......
Page 21: ...Multiview Seamless Switcher 02 Operating the Seamless Switcher...
Page 60: ...This page left intentionally blank...
Page 61: ...Multiview Seamless Switcher 03 Advanced Operation...
Page 86: ...This page left intentionally blank...
Page 87: ...Multiview Seamless Switcher 04 Appendix...