Y Series TechBook
45
If a keypad doesn’t work:
•
Verify keypad connections and try spare keypad
•
Replace keypad if problem is corrected
•
Replace pack if problem is not corrected
Keypad connector
Keypad doesn't seem to work step-by-step
GFCI trips
Warning!
Total current output cannot exceed total current
input rating!
There are different GFCI models used on the
market See manufacturer's instructions that come
with the GFCI for specific information Note that all
illustrations are examples only
From
electrical box To spa
Ground
wire
Main electrical box GFCI panel
Verify that GFCI is properly connected
If it's not, verify GFCI diagram and reconnect it
Verify the spa pack wiring (make sure that the neutral
and the ground have not been inverted)
From
electrical box
To spa
Important
connections:
Neutral of
GFCI must be
connected to
neutral bus.
Neutral from
spa must be
connected to
breaker.
If the GFCI is properly connected but still tripping,
unplug all outputs from the spa pack (pumps, blower,
heater, ozonator etc)
Reconnect one output at a time until the GFCI
trips again
Replace defective component
Note: Incorrect GFCI wiring may lead to a condition where
the GFCI may NOT trip when it should, causing electrical
shock hazard. All electrical installations should be done by
qualified personnel only.