Y Series TechBook
9
Installing the in.k200
The keypad should be installed directly onto the spa (or very close to it) so that it is easily accessible to the user
• To install the ink200, drill two 1” (25 mm) diameter holes at 2 5/8” (67 mm) from center to center as illustrated
• Cut out the material between the two holes (see illustration)
• Clean the installation surface and peel the adhesive backing from the keypad
• Insert keypad and align it correctly, then ensure it is properly glued by gently pressing evenly on the entire surface
If the keypad is equipped with an optional holder plate, remove the two wing nuts from the back of the keypad and
remove the mounting bracket
Insert the keypad into the opening you have cut out Put the mounting bracket and the wing nuts back on their
respective bolts and fix the keypad securely in place (see illustration below)
Note: It is the installer’s responsibility to ensure that no obstructions (cables, piping, etc.) are
present below the deck at the drill hole location.
Note: If the installation location is not perfectly even (e.g. wood surface), make a silicone joint
between the installation surface and the back of the unit to ensure a proper seal around it.
∅
1"
(25 mm)
Gasket with adhesive
2
5/8
"
67 mm
∅
1"
(25 mm)
∅
1"
(25 mm)
1" (25 mm)
dia drill
1"
(25 mm)
3
5/8
"
92 mm
Connecting the main keypad to the spa pack
The ink200 comes with a 10' (3048 m) cable and an inlink connector
To connect the ink200, first remove the cover (for inye 4 screws and for inyt 6 screws), then insert the inlink
connector into the appropriate keypad connector (as illustrated) Route the cable through one of the molded strain
relief channels on the bottom right side of the spa pack (as illustrated) Don’t forget to replace the cover and all
screws (do not over tighten cover screws)
Note: always shut power down before connecting an accessory to the in.ye or in.yt.
ink200
Connect the
main keypad
ink200 as
indicated here
in.k200 installation & connections