EN
4
Make sure that the pressing contour of the Geberit pressing
collar is positioned correctly on the fitting bead of the Geberit
pressfitting.
✓
The pressing collar is correctly positioned when the
centring plate is pointing towards the pipe.
5
Slide the locking lug over the locking pin until the locking pin
snaps into position 1 and the pressing collar firmly surrounds
the pressfitting.
6
Turn the closed Geberit pressing collar to the pressing
position.
7
Make sure that the release lever and locking lug form a line.
8
To open the Geberit adapter jaw ZB 323 or ZB 221, push
both jaw levers together.