ATTENTION
Leaking connection due to failed pressing sequence
▶
Make sure that the pressing collar is completely closed after
the pressing sequence.
▶
Have any Geberit pressing collars that have not been closed
completely, as well as the adapter jaw and pressing tool,
inspected by an authorised repair shop.
▶
Replace any connections that have not been pressed
correctly. They must not be pressed again.
▶
If there are any burrs on the pressfitting after the pressing
procedure, have the pressing collar and the adapter jaw
tested by an authorised repair shop.
10
Open the Geberit adapter jaw and remove it from the
Geberit pressing collar.
CAUTION
Danger of cutting due to sharp edges on the Geberit
pressfitting
Defective Geberit pressing collars can cause sharp edges
to form on the Geberit pressfitting.
▶
Only use pressing collars that are in perfect working
order and are maintained.
▶
Check the pressfitting for sharp edges after the
pressing procedure and replace the pressing collar if
necessary or have it tested by an authorised repair
shop.
11
Open the Geberit pressing collar and detach it.