EN
15
Release both jaw levers.
CAUTION
Danger of crushing
▶
Keep your hands at a safe distance from the Geberit
pressing collar and adapter jaw.
16
Press the Geberit pressfitting. See operating instructions for
the relevant pressing tool.
✓
The locking pin is in position 3.
17
After the pressing procedure, check that the Geberit
pressing collar is fully closed.
ATTENTION
Leaking connection due to failed pressing sequence
▶
Make sure that the pressing collar is completely closed after
the pressing sequence.
▶
Have any Geberit pressing collars that have not been closed
completely, as well as the adapter jaw and pressing tool,
inspected by an authorised repair shop.
▶
Replace any connections that have not been pressed
correctly. They must not be pressed again.
▶
If there are any burrs on the pressfitting after the pressing
procedure, have the pressing collar and the adapter jaw
tested by an authorised repair shop.
18
Open the adapter jaw and remove it from the pressing collar.