polishing.
6.4
Pneumatic connections
6.4.1
Air requirement
The air requirement depends on the type of actuator fitted. The following tables
show guideline values at an air pressure supply of 6 bar per valve size and the
corresponding actuator size used as a standard.
Air requirement for spring-to-close actuators (NC)
Nominal width
of valve
Actuator
Reference
stroke
(RH1)
Reference air
pressure
(RL1)
Air requirement
at
RH1/RL1
[mm]
[bar]
[dm³N]
DN 25 / 1" OD
PA80 NC
10
6
0.84
DN 40 / 1 1/2" OD PA80 NC
12.5
6
0.93
DN 50 / 2" OD
PA100 NC
25
6
2.24
DN 65 / 2 1/2" OD PA100 NC
25
6
2.24
6.4.2
Establishing the Compressed Air Supply
A prerequisite for the reliable operation of the valve is that the compressed air
hoses are cut exactly square.
Tools required:
•
A hose cutter
Carry out the following steps:
1.
Depressurize the pneumatic connection at the place where you are working.
2.
Use the hose cutter to cut the pneumatic hoses square.
3.
Connect a hose to the valve.
®
The compressed air supply has been established.
Hint!
It must be possible to regulate the supply of compressed air for
precision control of the valve position. Therefore, the use of a
positioner is recommended. Various standard versions can be ordered
from the manufacturer, see Section 10.6, Page 35.
6.5
Electrical connections
Prerequisite:
•
The valve has been fitted correctly, see Section 10.7, Page 36.
•
Positioner is installed according to the respective manual. Overview of
positioners see section Section 10.6.1, Page 36.