10.6.1 Available positioners
Positioner with available actuators and mounting kits
Positioner
Actuator size
Material number of
the mounting kit
GEA Aseptomag AG
T.VIS P-15
PA60 – PA210
0984.00038
Siemens PS2
PA60 – PA210
0963.10000
Samson 3730-1, 3730-2,
3730-3
PA60 – PA80
0963.50081
PA100- PA210
0963.50067
Bürkert 8696
PA60
0963.50084
Bürkert 8692, 8694
PA80 – PA210
0963.50083
10.7
Disassembling and Assembling the Valve
10.7.1 Dismantling the Valve into its Main Components
Tools required:
•
Hex socket key
Caution!
Danger of injury due to spring force being released
You can sustain injuries to your fingers when you put your hand into a valve
if the valve has not been moved to the open position beforehand.
► Before starting any work, bring the valve to the "open" position.
► Wear protective gloves for all work.
► Always exercise caution and prudence.
Caution!
Danger of injury due to media escaping after removing the clamp
You can sustain injuries to your entire body if you open a valve that is still
under pressure from the medium.
► Ensure that the valve is no longer under medium pressure before
removing the clamp.
► Wear suitable protective clothing for all work.
► Always exercise caution and prudence.
Carry out the following steps:
1.
Bring the valve to the "closed" position.
Maintenance
Disassembling and Assembling the Valve
430BAL011926EN_1
36
30.08.2019
Summary of Contents for Aseptomag RVIN