Examples of relevant process parameters are:
•
daily period of use,
•
switching frequency,
•
type and temperature of the product,
•
type and temperature of the cleaning solution,
•
ambient conditions.
If information regarding the definition of practical-oriented maintenance intervals
is not available or is insufficient, the guideline values listed in the "Maintenance"
chapter can be referred. This information is based on empirical values for GEA
Flow Components and relates to installations working in two-shift operation.
10.4
List of tools
List of tools (in alphabetical order)
Tool
Figure
Intended Purpose
Material Number
GEA Aseptomag AG
Pressurizing tool
DN 15 - DN 80
Fig.7
Valves
DN 15 - DN 80
Inspection of metal
bellows
0980.50003
S-12-0010
Pressure control valve
Ø 6 mm
Fig.8
Inspection of metal
bellows
9999.10090
Flexible head spanner
Ø60-90mm,
Pin Ø 5.5mm
Fig.9
PA80-135
Remove/fit assembly
spring
0980.10009
S-12-0332