Compressed air supply
Compressed air supply
6 bar, compressed air filtered (at least 0,5 µm), oil-free.
Cleaning
Cleaning
The valve is suitable for CIP cleaning (Cleaning in Place)
Recommended cleaning speed
in the valve
At least 2 m/s
Sterilisation
Sterilisation
The valve is suitable for SIP sterilisation (Sterilisation in Place)
Sterilisation with
Hot water, max. 160 °C (320 °F)
Steam, max. 160 °C (320 °F)
Chemicals (e.g. H
2
O
2
)
5.2
Control parameters
Hint!
A positioner with a corresponding mounting kit converts the valve into
the functioning regulating unit. (Overview of positioner, see
Section 10.6.1, Page 36)
Gate valve
Size DN
Size OD
Available KVS values [m
3
/h]
DN 25
OD 1"
9.8
DN 40
OD 1 1/2"
18
DN 50
OD 2"
35
DN 65
OD 2 1/2"
56
Technical data
Control parameters
430BAL011926EN_1