Complete Accessory List

Kit Number

Description                                                                              

                   For Additional Information Refer to Pages

RAK3152

Line cord power connection kit - 230/208 V - 2.61/2.19 kW - 15 amp

11 & 12

RAK3202

Line cord power connection kit - 230/208 V - 3.42/2.87 kW - 20 amp

11 & 12

RAK3302

Line cord power connection kit - 230/208 V - 4.81/4.07 kW - 30 amp

11 & 12

RAK4157

Direct connect power connection kit - 230/208 V - 2.61/2.19 kW - 15 amp

11 & 12

RAK4207

Direct connect power connection kit - 230/208 V - 3.42/2.87 kW - 20 amp

11 & 12

RAK4307

Direct connect power connection kit - 230/208 V - 4.81/4.07 kW - 30 amp

11 & 12

RAK5157

Direct connect power connection kit - 265 volt - 2.71 kW - 15 amp

11 & 12

RAK5207

Direct connect power connection kit - 265 volt - 3.55 kW - 20 amp

11 & 12

RAK5307

Direct connect power connection kit - 265 volt - 5.03 kW - 30 amp

11 & 12

RAK148D1

Digital thermostat for heat pump - single stage cool - two stage heat

11 & 12

RAK148P1

Digital programmable t’stat for heat pump - single stage cool - two stage heat

11 & 12

RAK164D1

Digital t’stat for resistance heat unit - single stage cool - single stage heat

11 & 12

RAK164P1

Digital programmable t’stat - resistance heat unit- single stage cool - single stage heat

11 & 12

RAVAL1

Exterior grille

10 & 15

RAVRG1

Access panel for return air

11 & 15

RAVRMS

Freeze Sentinel

/temperature limiting room air sensor 

6 & 12

RAVRG2

Return Air Grille for flush door  

11 & 15

RAVWP6

Wall Plenum for walls up to 6" thick

10 & 15

RAVWP8

Wall Plenum for walls up to 8" thick

10 & 15

RAVWP12

Wall Plenum for walls up to 12" thick

10 & 15

RAVWP15

Wall Plenum for walls up to 15" thick

10 & 15

RAVHW1

Hydronic kit, single row heat; exchanger - 9k and 12k models only

14

RAVHW2

Hydronic kit, double row heat; exchanger - 9k, 12k  and 18k models only

14

RAVHW3

Hydronic kit, triple row heat; exchanger - 12k and 18k models only

14

Unit Specifications

AZ85E09DAC

AZ85E12DAC

AZ85E18DAC

AZ85H09DAC

AZ85H12DAC

AZ85H18DAC

230/208 Volt Models

Electric resistance heat

Heat pumps

Features

BTUH

9,000/8,800

11,700/11,500

17,900/17,700

8,800/8,600

11,700/11,500

17,800/17,700

Watts

860/840

1105/1090

1870/1850

840/820

1105/1090

1860/1850

E.E.R.

10.5/10.5

10.6/10.6

9.3/9.3

10.5/10.5

10.6/10.6

9.3/9.3

Cool Amps

4.1/4.4

5.2/5.7

8.9/9.8

4.1/4.4

5.2/5.7

8.9/9.8

Dehumidification 

(pints/hr.)

2.5

3.2

5.0

2.5

3.2

5.0

SHR

0.81

0.79

0.71

0.83

0.79

0.69

Reverse Cycle (BTUH)

N/A

N/A

N/A

8,200/8,000

10,400/10,300

16,400/16,200

COP @ 47°

N/A

N/A

N/A

3.4/3.4

3.4/3.4

3.0/3.0

Indoor CFM (Hi/Med/Lo)

520/460/360

590/500/380

600/520/400

520/460/360

590/500/380

600/520/400

Unit Width (in.)

23-1/8

23-1/8

23-1/8

23-1/8

23-1/8

23-1/8

Unit Depth (in.)

23-1/8

23-1/8

23-1/8

23-1/8

23-1/8

23-1/8

Unit Height (in.)

32-1/4

32-1/4

32-1/4

32-1/4

32-1/4

32-1/4

Ship Wt.

159

161

178

162

165

179

Net Wt.

146

148

165

149

152

166

AZ85E09EAC

AZ85E12EAC

AZ85E18EAC

AZ85H09EAC

AZ85H12EAC

AZ85H18EAC

265 Volt Models

Electric resistant heat

Heat pumps

Features

BTUH

9,000

11,700

17,900

8,800

11,700

17,800

Watts

860

1105

1870

840

1105

1860

E.E.R.

10.5

10.6

9.3

10.5

10.6

9.3

Cool Amps

3.5

4.5

7.8

3.5

4.5

7.8

Dehumidification 

(pints/hr.)

2.5

3.2

5.0

2.5

3.2

5.0

SHR

0.82

0.80

0.70

0.83

0.79

0.70

Reverse Cycle (BTUH)

N/A

N/A

N/A

8,200

10,400

16,400

COP @ 47°

N/A

N/A

N/A

3.4

3.4

3.0

Indoor CFM (Hi/Med/Lo)

520/460/360

590/500/380

600/520/400

520/460/360

590/500/380

600/520/400

Unit Width (in.)

23-1/8

23-1/8

23-1/8

23-1/8

23-1/8

23-1/8

Unit Depth (in.)

23-1/8

23-1/8

23-1/8

23-1/8

23-1/8

23-1/8

Unit Height (in.)

32-1/4

32-1/4

32-1/4

32-1/4

32-1/4

32-1/4

Ship Wt.

159

161

178

162

165

179

Net Wt.

146

148

165

149

152

166

265 Volt available by special order only.

Summary of Contents for Zoneline

Page 1: ...GE Zoneline vertical packaged terminal air conditioners 2010 Architects and Engineers Data Manual...

Page 2: ...cooling with electric resistance heat H heat pump with electric resistance heat W Cool only Zoneline packaged terminal unit Voltage Phase Frequency D 230 208 Volt single phase 60 Hz E 265 Volt single...

Page 3: ...rm Specifications 17 Additional Specifications 18 Warranty 19 Important Notice Equipment used as a primary source for heating or cooling is an integral part of the building in which it is installed Pr...

Page 4: ...mounted under the window there are limitations to furniture placement and curtains cannot hang to the floor Finally some people find the controls difficult to adjust for the desired temperature To ad...

Page 5: ...dehumidification Unique sleeve design for easier installation and service Three way slide out chassis service maintenance flexibility Electronic Temperature Limiting requires room air temperature sen...

Page 6: ...Temperature Limiting feature requires the use of the optional room air temperature sensor model RAVRMS Designed to be mounted on the wall of the unit enclosure closet the Room Air Temperature Sensor a...

Page 7: ...mmends a 28 wide door A 20 3 8 wide by 20 3 8 high cutout is required in the door to accommodate the grille and filter bracket Only one filter is to be used in the installation Multiple filters will r...

Page 8: ...in operating conditions frost can form on the indoor coil of an air conditioner reducing air flow and causing a lack of cooling complaint In order to prevent frost from forming the ZVAC has an automat...

Page 9: ...he room through this screened vent opening is not conditioned This unconditioned air becomes mixed with the conditioned air that is circulated by the ZVAC indoor fan This air mixture generates an addi...

Page 10: ...to raise the platform a minimum of 8 12 recommended and have a minimum load bearing capacity of 175 pounds The platform legs must be positioned so access to the unit drain connection is not blocked C...

Page 11: ...20 amp or 30 amp circuit The amount of resistance heat is determined by the selection of the correct power connection kit This is the same type of connection used by GE for years in the Premium and De...

Page 12: ...For all installations feeder sub feeder branch circuit and electrical protective devices must conform to all local codes In the absence of a local code the National Electrical Code should be followed...

Page 13: ...ger 9k 12k and 18k models only 14 RAVHW3 Hydronic kit triple row heat exchanger 12k and 18k models only 14 Unit Specifications AZ85E09DAC AZ85E12DAC AZ85E18DAC AZ85H09DAC AZ85H12DAC AZ85H18DAC 230 208...

Page 14: ...ltage 60 Hertz 230 208 230 208 230 208 230 208 230 208 230 208 230 208 Heating capacity designed to meet standard ARI rating conditions of 200 F water entering temp 180 F water exiting temp 70 F enter...

Page 15: ...Thermostat Heat Cool Hydronic Models 4 wire 5 wire Heat Pump Models 6 wire 6 wire Check the thermostat instructions for correct wiring and installation requirements 30 50 22 1 2 22 1 2 Cutout Dimensio...

Page 16: ...ough SIDE of case 3 min from two sides of case Plenum cutout 32 1 4 H x 20 W Drain fitting 3 4 Drain line Outside wall Platform Wall plenum Field supplied outer flashing A B A Minimum recommended acce...

Page 17: ...have a positive cooling condensate disposal system which meets the test requirements of applicable A R I standard 310 380 and 390 The disposal system shall have a slinger ring on the outdoor fan to di...

Page 18: ...dditional Specifications Service Submit complete information with bid covering service availability to whom service on units will be assigned complete address and phone number including phone number o...

Page 19: ...cessary maintenance Failure or damage resulting from corrosion due to installation in an environment containing corrosive chemicals Failure or damage resulting from corrosion due to installation in a...

Page 20: ...GE tradition of quality and innovation continues GE has a policy of continuous improvement of its products and reserves the right to change materials and specifications without notice 2010 General Ele...

Reviews: