GFK-1911B
Appendix D The NIU GSD File
D-19
D
; 2-1: less modules configured than connected
; 2-2: less modules connected than configured
; 2-3: 1st byte of special signature format is incorrect
; 2-4: for last module not enough byte of special signature
format configured
; 2-5: sum of configured process data > 176 byte
; 2-6: different ID codes for configuration and module
; 2-7: different length codes for configuration and module
; 2-8: number of manufacturer specific data is incorrect
; 2-9: not enough output byte configured
; 2-10: not enough input byte configured
; 2-11: configuration of PROFIBUS needs more than 244 byte
; 2-12: internal list too small
; 3: configuration error INTERBUS Inline station
; 3-1: module type not allowed
; 3-2: module length code zero not allowed
; 3-3: module length code > 32 byte not allowed
; 3-4: Loop1 module not allowed
; 3-5: sum of INTERBUS process data too large (>250 Byte)
; 3-6: more than 64 modules connected
; 3-7: sum of PROFIBUS process data > 176 Byte
; 3-8: more than 8 PCP devices connected
; 4: INTERBUS error
; 4-1: local bus error (Data In)
; 4-2: local bus error (Data Out)
; 4-3: error can not be localized
; 4-4: INTERBUS Inline module not ready
; 4-5: new INTERBUS module has an incorrect length- or ID-
code
; 4-6: additional INTERBUS Inline module(s) connected
; 5: module error
; 5-1: peripheral fault
; 6: parameterization error local bus
; 6-1: pcp telegram could not be sended
; Byte 12 INTERBUS Inline ID code
; Byte 13 INTERBUS Inline length code
; Byte 14 Firmware revision, ASCII coded
;********************************************
;****** error location (Status PDU format) *******
Unit_Diag_Area = 8-15
Value(1) = "Module 1"
Value(2) = "Module 2"
Value(3) = "Module 3"
Value(4) = "Module 4"
Value(5) = "Module 5"
Value(6) = "Module 6"
Value(7) = "Module 7"
Value(8) = "Module 8"
Value(9) = "Module 9"
Value(10) = "Module 10"
Value(11) = "Module 11"
Value(12) = "Module 12"
Value(13) = "Module 13"
Value(14) = "Module 14"
Value(15) = "Module 15"
Value(16) = "Module 16"
Value(17) = "Module 17"
Value(18) = "Module 18"
Value(19) = "Module 19"
Value(20) = "Module 20"
Value(21) = "Module 21"
Value(22) = "Module 22"
Value(23) = "Module 23"
Value(24) = "Module 24"
Value(25) = "Module 25"
Value(26) = "Module 26"
Value(27) = "Module 27"
Value(28) = "Module 28"
Value(29) = "Module 29"
Value(30) = "Module 30"
Value(31) = "Module 31"
Value(32) = "Module 32"
Value(33) = "Module 33"
Value(34) = "Module 34"
Value(35) = "Module 35"
Value(36) = "Module 36"
Value(37) = "Module 37"
Value(38) = "Module 38"
Value(39) = "Module 39"
Value(40) = "Module 40"
Value(41) = "Module 41"
Value(42) = "Module 42"
Value(43) = "Module 43"
Value(44) = "Module 44"
Value(45) = "Module 45"
Value(46) = "Module 46"
Value(47) = "Module 47"
Value(48) = "Module 48"
Value(49) = "Module 49"
Value(50) = "Module 50"
Value(51) = "Module 51"
Value(52) = "Module 52"
Value(53) = "Module 53"
Value(54) = "Module 54"
Summary of Contents for VersaPoint IC220PBI002
Page 4: ......
Page 10: ...Contents x VersaPoint I O System Profibus DP NIU User s Manual August 2005 GFK 1911B...
Page 80: ...5 14 VersaPoint I O System Profibus DP NIU User s Manual August 2005 GFK 1911B 5...
Page 100: ...6 20 VersaPoint I O System Profibus DP NIU User s Manual August 2005 GFK 1911B 6...
Page 166: ...A 10 VersaPoint I O System Profibus DP NIU User s Manual August 2005 GFK 1911B A...